Kenmore 153.32116, 153.32118 manual Display Shows, Indicates, Corrective Action

Models: 153.32116 153.32118

1 28
Download 28 pages 36.51 Kb
Page 23
Image 23
DISPLAY SHOWS

DISPLAY SHOWS

 

INDICATES

UPPER ELEMENT

1.

Upper element

is not

CONNECT

 

functioning

 

FAU LT

 

 

 

LOWER ELEMENT

1.

Lower element

is not

CONNECT

 

functioning

 

FAU LT

 

 

 

HEAT PUMP

 

1.

Heat Pump compressor

is

CONNECT

 

 

not functioning.

 

 

FAU LT

 

 

 

 

 

 

 

FAN

 

 

1.

Heat Pump fan is not

 

CONNECT

 

 

functioning.

 

 

FAU LT

 

 

 

 

 

 

 

AMBIENT

TEMP

 

1.

Ambient

Temperature

 

SENSOR

SHORT

OR

 

Sensor

is not functioning.

 

OPEN OR AD ERROR

 

 

 

 

 

UPPER TEMP

 

1.

Upper Temperature

Sensor

SENSOR

SHORT

OR

 

is not functioning.

 

 

OPEN OR AD ERROR

 

 

 

 

 

LOWER

TEMP

 

1.

Lower Temperature

Sensor

SENSOR

SHORT

OR

 

is not functioning.

 

 

OPEN OR AD ERROR

 

 

 

 

 

DISCHARGE TEMP

1.

Discharge Temperature

 

SENSOR

SHORT OR

 

Sensor

is not functioning.

 

OPEN OR AD ERROR

 

 

 

 

 

COIL TEMP

 

1.

Coil Temperature Sensor

is

SENSOR

FAULT

 

 

not functioning.

 

 

OR AD ERROR

CORRECTIVE ACTION

1.Turn off power at the circuit breaker/fuse box and check for a loose connection at the element. For access directions

see "Element Removal/Replacement" section. If error persists proceed to the next step.

2.Replace non-functioning element. See "Element Removal/ Replacement" section.

1.Turn off power at the circuit breaker/fuse box and check for a loose connection at the element. For access directions see "Heating Element Replacement" section. If error

persists proceed to the next step.

2.Replace non-functioning element. See "Element Removal/ Replacement" section.

IMPORTANT: Using an element greater than 2000 watts in place of the lower element will damage the water heater.

1.Contact a qualified person to service the heat pump.

1.Contact a qualified person to service the unit.

1.Contact a qualified person to service the unit.

1.Contact a qualified person to service the unit.

1.Contact a qualified person to service the unit.

1.Contact a qualified person to service the unit.

1.Contact a qualified person to service the unit.

MAIN CIRCUIT BOARD FAU LT

HIGH TEMP

LOCKOUT

CONDENSATE

DRAIN

ALARM

(If Accessory Condensate Pump is Installed)

1.Main Circuit Board is not functioning.

1.Water temperature in unit has exceeded 190° F.

1.Condensate pump failure.

1.Contact a qualified person to service the unit.

1.See "High Temperature Shut-off System" section.

1.Check to see if accessory condensate pump is plugged in and has power. Also check circuit breaker/fuse box and GFCI (if used), if error persists proceed to the next step.

2.Check condensate pump outlet tube for blockage, if error persists proceed to the next step.

3.Check control wire connections to condensate pump. If error

persists proceed to the next step.

4.Replace accessory condensate pump. If error persists contact a Qualified Person.

LOW WATER

LEVEL ALARM

COMMUNICATION ERROR

ELECTRONIC POWER ANODE ERROR #0-9

(# CAN BE 0-9)

1.

Not enough water in the

1. Fill Completely - Open all hot water taps in home and

run

 

tank.

until water (uninterrrupted by air) flows from all open

hot

 

(Tank not full)

water taps.

 

1.No communication between 1. Contact a qualified person to service the unit. mainboard and user

interface board.

1.Indicates the power anode is 1. Contact a qualified person to service the unit. not operating properly

NOTE: The diagnostic codes listed above are the most common. If a diagnostic code not listed above is displayed, contact Sears Repair Services at 1-800-4-MY-HOME (1-800-469-4663).