Kenmore 153.32966, 153.329461, 153.32956, 153.329861 heaterjunctionboxfortheconduitconnection

Models: 153.32956 152.329361 153.32936 153.329262 153.32986 153.329263 153.329561 153.329861 153.329461 153.32966 153.320661 153.32946

1 32
Download 32 pages 17.71 Kb
Page 15
Image 15
4,Astandard1/2"conduitopeninghasbeenmadeinthewater

Thelengthinanygroundreturnpathdoesnotexceed 6feet,

Thecircuitconductorscontainedthereinareprotected byovercurrentdevicesratedat20amperesorless,

Theconduitortubingisterminatedfittingsapproved forgrounding,

Forcompletegroundingdetailsandallallowableexceptions, refertothecurrenteditionoftheNEC-NationalElectricalCode NFPA70,

4,Astandard1/2"conduitopeninghasbeenmadeinthewater

heaterjunctionboxfortheconduitconnection,

5, WiringDiagrams,see"Wiring Diagrams" section have been

supplied showing the two most common types of connections between the water heater and the power supply.

You can easily see which type connection you have by removing the junction box cover on top of the water heater,

Two Wire Connection Diagrams: is the most common requiring you to simply connect red to red, black to black, and the ground wire to the green ground screw in the junction box of the water heater.

Three Wire Connection Diagram: is used when you

are connecting the water heater to a power supply that has a "Time Clock" or "Off Peak" meter, To make

these connections refer to block 1 or 2 in this wiring diagram for the type of system you have,

6,

8,

NOTE: If you have purchased a three wire connection water heater but you are not on a 'Time Clock" or 'Off Peak" meter

and have a standard two wire connection power supply, simply follow the connection diagram in block 3 of the three

wire connection diagram,

Use wire nuts and connect the power supply wiring to the wires inside the water heater's junction box,

The water heater must be electrically "grounded" by the installer. A green ground screw has been provided on the

water heater's unction box, Connect ground wire to this location.

Replace the wiring junction cover using the screw provided,

CONDU_T

GREEN

GROUND

SCREW

FIGURE 23.

15

Page 15
Image 15
Kenmore 153.32966, 153.329461 heaterjunctionboxfortheconduitconnection, 4,Astandard1/2conduitopeninghasbeenmadeinthewater