Kenmore 153.32986 AbbreviationsFoundInThisnstructionManual, UL= UnderwritersLaboratoriesInc

Models: 153.32956 152.329361 153.32936 153.329262 153.32986 153.329263 153.329561 153.329861 153.329461 153.32966 153.320661 153.32946

1 32
Download 32 pages 17.71 Kb
Page 5
Image 5
AbbreviationsFoundInThis{nstructionManual:

ThankYouforpurchasingSearswaterheaterProperly. instalbdandmaintained,it shouldgiveyouyearsoftrouble freeserviceItisstronglysuggestedthatthisnewwaterheater. beprofessionallyinstalled,contactthelocalSearsService CenteroranySearsstoreTheywillarrangeforprompt,quality. installationbySearsauthorizedcontractors.

AbbreviationsFoundInThis{nstructionManual:

UL= UnderwritersLaboratoriesInc,

NEC= National Electrical Code

ANSI = American National Standards Institute

Read the "General Safety" section, page 3 of this manual first and then the entire manual carefully. If you don't follow the safety rules, the water heater wil! not operate properly. It could cause DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE.

This manual contains instructions for the installation,

operation, and maintenance of this ebctric water heater. It also contains warnings throughout the manual that you must read and be aware of. Ai! warnings and all instructions are essential to the proper operation of the water heater and your safety. Since we cannot put everything on the first few

pages, READ THIS ENTIRE MANUAL BEFORE ATTEMPTING TO INSTALL OR OPERATE THE WATER HEATER.

The installation must conform with the instructions in this manual; electric company rules; and Local Codes, or in the

absence of Local Codes, with the current edition of the NEC o National Electrical Code, NFPA 70. This publication

is availabb from your local government or public library or

electric company or by writing Underwriters Laboratories

Inc., 333 Pfingsten Road, Northbrook, IL 60062.

If after reading this manual you have any questions or do

not understand any portion of the instructions, call Sears Service Center.

Carefully plan the place where you are going to put the water

heater. Correct electrical wiring and connections are very important in preventing death from possible electrical shock and fires.

Examine the location to ensure the water heater complbs with the "Facts to Consider About the Location" section.

For California installation this water heater must be braced,

anchored, or strapped to avoid falling or moving during an

earthquake. See instructions for correct installation procedures.

Instructions may be obtained from the California Office of the

State Architect, 400 P Street, Sacramento, CA 95814.

Massachusetts Code requires this water heater to be installed

in accordance with Massachusetts 248oCMR 2.00; State

Plumbing Code and 248-CMR 5.00. In the Commonwealth of

Massachusetts, this product must be installed by a licensed plumber or gasfitter.

 

TANK

 

DBMENSBONS

 

 

ELEMENT

 

MAXBMUM FUSE

 

 

RECOVERY

RATE

WATTAGE

MINtMUM

OR qRCUr

 

CAPACITY

 

iN iNCHES (rnm)

MODEL

 

GALS.PER

HOUR

@240

VOLTS

WiRE SIZE*

BREAKER

 

 

 

 

 

 

 

NUMBER

Gab

Liters

DBA.

HEIGHT

@90°F Rise

UPPER

LOWER

{GAUGE)

SiZE (AMPS}

 

 

 

 

 

 

 

 

153.329262

38

144

25

(635)

31.5

(800)

17.3

 

3800

3800

12

20

153.329263

25.0

 

3800

5500

10

30

 

 

 

 

 

 

 

 

153.329360

30

114

19 (483)

47

(1,194)

17.3

 

3800

3800

12

20

153.329361

25.0

 

3800

5500

10

30

 

 

 

 

 

 

 

 

153.329460

40

151

19 (483)

60

(1,524)

17.3

 

3800

3800

12

20

153.329481

25.0

 

3800

5500

10

30

 

 

 

 

 

 

 

 

 

 

 

153.329560

55

208

21.5

(546)

61

(1,549)

17.3

 

3800

3800

12

20

153.329561

25.0

 

3800

5500

10

30

 

 

 

 

 

 

 

 

 

 

 

153.329660

66

250

23

(584)

61

(1,549)

17.3

 

3800

3800

12

20

153.329681

25.0

 

3800

5500

10

30

 

 

 

 

 

 

 

 

153.329880

80

303

25

(635)

61.5

 

(1,562)

173

 

3800

3800

12

20

153.329861

 

25.0

 

3800

5500

10

30

 

 

 

 

 

 

 

 

Wiring size based on standard 60°C copper wire. If distance from fuse box to water heater is more than 90 feet, refer to your local electrical code.

Page 5
Image 5
Kenmore 153.32986, 153.329461, 153.32956 AbbreviationsFoundInThisnstructionManual, UL= UnderwritersLaboratoriesInc