Location Requirements

Carbon Monoxide Poisoning Hazard

Do not install in a mobile home.

Do ng so can resu t n carbon monox de po son ng and death.

The FVIR System is designed to reduce the risk of flammable vapor-related fires. The patented system protects your family by trapping the burning vapors within the water heater combustion chamber through the special flame-arrestor. The burning vapors literally "burn themselves out" without escaping back into the room. In the event of a flammable vapor incident, the FVIR System disables the water heater by shutting off the gas supply to the water heater's burner and pilot, preventing re-ignition of any remaining flammable vapors in the area. This will not prevent a possible fire/explosion if the igniter is depressed and flammable vapors have accumulated in the combustion chamber with the pilot light off. If you suspect a flammable vapor incident has occurred, do not use this appliance. Do not attempt to light this appliance, or depress the igniter button if you suspect flammable vapors have accumulated inside or outside the appliance. Immediately call a qualified technician to inspect the appliance. Water heaters subjected to a flammable vapors incident will show a discoloration on the flame-arrestor and require replacement of the entire water heater.

FIRE AND EXPLOSION HAZARD

Can result in serious injury or death

_Do not store or use gasoline or other flammable

vapors and liquids in the vicinity of this or any other appliance. Storage of or use of gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance can result in serious injury or death.

Read and follow water heater warnings and instructions.

Do not use or store flammable products such as gasoline, solvents, or adhesives in the same room or area near the water heater. If such flammables must be used, all gas burning appliances in the vicinity must be shut off and their pilot lights extinguished. Open the doors and windows for ventilation while flammable substances are in use.

If flammable liquids or vapors have spilled or leaked in the area of the water heater, leave the area immediately and call

the fire department from a neighbor's home. Do not attempt to clean the spill until all ignition sources have been extinguished.

Fire or Explosion Hazard

Read instruction manual before installing, using or servicing water heater.

Improper use may result in fire or explosion.

Maintain required clearances to combustibles.

Keep combustibles such as boxes, magazines, clothes, etc. away from the water heater area.

Site Location

Select a location near the center of the water piping system. The water heater must be installed indoors and in a vertical

position on a level surface. DO NOT install in bathrooms, bedrooms, or any occupied room normally kept closed.

Locate the water heater as close to the chimney or gas vent as practical. Consider the vent system piping and combustion air supply requirements when selecting the

water heater location. The venting system must be able to run from the water heater to termination with minimal

length and elbows.

Locate the water heater near the existing gas piping. If installing a new gas line, locate the water heater to minimize the pipe length and elbows.

The water heater should be located in an area not subject to freezing temperatures. Water heaters located in unconditioned spaces (i.e., attics, basements, etc.) may require insulation of the water piping and drain piping to protect against freezing. The drain and controls must be easily accessible for operation and service. Maintain proper clearances as specified on the rating plate.

Do not locate the water heater near an air-moving device.

The operation of air-moving devices such as exhaust fans, ventilation systems, clothes dryers, fireplaces, etc., can affect the proper operation of the water heater. Special

attention must be given to conditions these devices may create. Flow reversal of flue gases may cause an increase of carbon monoxide inside of the dwelling (Figure 8).

If the water heater is located in an area that is subjected to lint and dirt, it may be necessary to periodically clean the base-ring filter and flame-arrestor (see External Inspection & Cleaning of the Base-Ring Filter; also see Cleaning the Combustion Chamber and Flame-Arrestor).

This water heater is not for use in manufactured (mobile) homes or outdoor installation.

NOTE: This water heater must be installed according to all local and state codes or, in the absence of local and state codes, the "National Fuel Gas Code", ANSI Z223.1(NFPA 54)-current edition.

!

REVERSE FLOW /--OF GASES

FIGURE 8

12

Page 12
Image 12
Kenmore 153.331592 Location Requirements, Site Location, Carbon Monoxide Poisoning Hazard, Fire or Explosion Hazard

153.331492, 153.331592 specifications

The Kenmore 153.331592 and 153.331492 are two innovative models in a series of versatile and efficient appliances designed to enhance everyday living. These products cater to a wide range of household needs, making them not only practical but also integral to modern home technology.

One of the standout features of the Kenmore 153.331592 is its energy efficiency. Designed with advanced technology, this model consumes less energy while providing robust performance. This is particularly important for environmentally conscious consumers looking to reduce their carbon footprint without compromising on effectiveness. The appliance utilizes smart energy management systems that optimize power use, ensuring that households can enjoy high performance with minimal energy costs.

On the other hand, the Kenmore 153.331492 offers impressive capacity, making it ideal for larger families or those who frequently entertain guests. This model is designed to accommodate substantial loads, whether it be laundry, cooking, or storage, making it a perfect fit for busy households. Additionally, its spacious design allows for easy organization, ensuring that items can be stored efficiently without clutter.

Both models incorporate advanced technology, including intuitive digital controls. These controls allow users to easily set preferences and monitor their appliance's operation through user-friendly interfaces. Smart connectivity features are also integrated into both models, allowing for remote management via smartphone apps. Users can adjust settings, receive alerts, and even perform diagnostics from the convenience of their phones, highlighting Kenmore's commitment to convenience and ease of use.

In terms of build quality, both models exhibit durable construction with high-quality materials designed to withstand the rigors of daily use. The sleek and modern design enhances their aesthetic appeal, making them suitable for any kitchen or laundry room decor.

Additionally, safety features such as auto shut-off, child locks, and overload protection are included in both models, ensuring that they operate smoothly without unnecessary risks.

In conclusion, the Kenmore 153.331592 and 153.331492 stand out for their blend of efficiency, capacity, and smart technology integration. These models present a compelling choice for those seeking reliable appliances that cater to both traditional and modern lifestyles. With a focus on energy conservation, user-friendly interfaces, and durable build quality, Kenmore continues to solidify its reputation as a leader in home appliance innovation.