-_._VENT

 

TOP

li

TF- BACK

SIDES

TOP --

SIDESII f

VIEW

l

 

 

FIGURE 10.

 

Open the cold water supply valve to the water heater. NOTE: The cold water supply valve must be left open when the water heater is in use.

To ensure complete filling of the tank, allow air to exit by opening the nearest hot water faucet. Allow water to run until a constant flow is obtained. This will let air out of the water heater and the piping.

Check all water piping and connections for leaks. Repair as needed.

Filling the Water Heater

Never use this water heater unless it is completely full of water. To prevent damage to the tank, the tank must be filled with water. Water must flow from the hot water faucet before turning "ON" gas to the water heater. To fill the water heater with water:

Close the water heater drain valve by turning the handle to the right (clockwise). The drain valve is on the lower front of the water heater.

Explosion Hazard

Use a new CSA approved gas supply line.

Install a shut-off valve.

Do not connect a natural gas water heater to an L.P. gas supply.

Do not connect an L.P. gas water heater to a natural gas supply.

Failure to follow these instructions can result in

death, explosion, or carbon monoxide poisoning.

Gas Requirements

IMPORTANT: Read the rating plate to be sure the water heater is made for the type of gas you wilt be using in your home. This information wilt be found on the rating plate located near the gas control valve/thermostat. If the information does not agree with the type of gas available, do not install or light. Call your dealer.

NOTE: An odorant is added by the gas supplier to the gas used by this water heater. This odorant may fade over an extended period of time. Do not depend upon this odorant as an indication of leaking gas.

Gas Piping

The gas piping must be installed according to all local and state

Property Damage Hazard

Avoid water heater damage.

Fill tank with water before operating.

codes or, in the absence of local and state codes, the "National Fuel Gas Code", ANSI Z223.1(NFPA 54)-current edition.

Table 1 on the following page provides a sizing reference for commonly used gas pipe materials. Consult the "National Fuel Gas Code" for the recommended gas pipe size of other materials.

Refer to Figure 11 for the items below.

1.Install a readily accessible manual shut-off valve in the gas supply line as recommended by the local utility. Know the location of this valve and how to turn off the gas to this unit.

2.Install a drip leg (if not already incorporated as part of the water heater) as shown. The drip leg must be no less than three inches tong for the accumulation of dirt, foreign material, and water droplets.

3.Install a ground joint union between the gas control valve/ thermostat and the manual shut-off valve. This is to allow

easy removal of the gas control valve/thermostat.

4.Turn the gas supply on and check for leaks. Test all

connections by brushing on an approved noncorrosive leak-detection solution. Bubbles will show a leak. Correct

any leak found.

MANUAL GAS_

SHUT-OFF VALVE---...._._

GROUND------_

JOINT

UNION

CHECK WITH

LOCAL UTILITY

FOR MINIMUM HEIGHT

3" MINIMUM

 

 

-_

6"

MAXIMUM

DRIP LEG--_'

AIR

GAP

SUITABLE DRAIN

 

 

FIGURE 11.

14

Page 14
Image 14
Kenmore 153.331592, 153.331492 owner manual Filling the Water Heater, Gas Requirements, Gas Piping, Explosion Hazard

153.331492, 153.331592 specifications

The Kenmore 153.331592 and 153.331492 are two innovative models in a series of versatile and efficient appliances designed to enhance everyday living. These products cater to a wide range of household needs, making them not only practical but also integral to modern home technology.

One of the standout features of the Kenmore 153.331592 is its energy efficiency. Designed with advanced technology, this model consumes less energy while providing robust performance. This is particularly important for environmentally conscious consumers looking to reduce their carbon footprint without compromising on effectiveness. The appliance utilizes smart energy management systems that optimize power use, ensuring that households can enjoy high performance with minimal energy costs.

On the other hand, the Kenmore 153.331492 offers impressive capacity, making it ideal for larger families or those who frequently entertain guests. This model is designed to accommodate substantial loads, whether it be laundry, cooking, or storage, making it a perfect fit for busy households. Additionally, its spacious design allows for easy organization, ensuring that items can be stored efficiently without clutter.

Both models incorporate advanced technology, including intuitive digital controls. These controls allow users to easily set preferences and monitor their appliance's operation through user-friendly interfaces. Smart connectivity features are also integrated into both models, allowing for remote management via smartphone apps. Users can adjust settings, receive alerts, and even perform diagnostics from the convenience of their phones, highlighting Kenmore's commitment to convenience and ease of use.

In terms of build quality, both models exhibit durable construction with high-quality materials designed to withstand the rigors of daily use. The sleek and modern design enhances their aesthetic appeal, making them suitable for any kitchen or laundry room decor.

Additionally, safety features such as auto shut-off, child locks, and overload protection are included in both models, ensuring that they operate smoothly without unnecessary risks.

In conclusion, the Kenmore 153.331592 and 153.331492 stand out for their blend of efficiency, capacity, and smart technology integration. These models present a compelling choice for those seeking reliable appliances that cater to both traditional and modern lifestyles. With a focus on energy conservation, user-friendly interfaces, and durable build quality, Kenmore continues to solidify its reputation as a leader in home appliance innovation.