Gas Pressure

Explosion Hazard

Gas leaks can not always be detected by smell.

Gas suppliers recommend that you use a gas detector approved by UL or CSA.

For more information, contact your gas supplier.

If a gas leak is detected, follow the "What to do if you smell gas" instructions on the cover of this manual.

Gas Pressure Testing

IMPORTANT: This water heater and its gas connection must be leak tested before placing the appliance in operation.

If the code requires the gas lines to be tested at a pressure exceeding 14" W.C., the water heater and its manual shut-off valve must be disconnected from the gas supply piping system and the line capped.

If the gas lines are to be tested at a pressure tess than 14" W.C., the water heater must be isolated from the gas supply piping system by closing its manual shut-off valve.

NOTE: Air may be present in the gas lines and could prevent the pilot from lighting on initial start-up. The gas lines should be purged of air by a qualified technician after installationof the gas piping system. While purging the gas piping system of air, ensure that the fuel is not spilled in the area of the water heater installation, or any source of ignition. If the fuel is spilled while purging the

piping system of air follow the "WHAT TO DO IF YOU SMELL GAS" instructions on the cover of this manual.

IMPORTANT: The gas supply pressure must not exceed the maximum supply pressure as stated on the water heater'srating plate. The minimum supply pressure is for the purpose of input adjustment.

Table 1

Natural Gas Pipe Capacity Table (Cu. Ft./Hr.)

Capacityof gas pipe of different diametersand lengths in cu. ft. per hr. with pressuredrop of 0.3 in. and specific gravity of 0.60 (naturalgas).

Nominal Iron Pipe

 

 

 

 

Length of Pipe,Feet

 

 

 

 

 

 

Size,in.

10

20

30

40

50

60

70

80

90

100

125

150

175

200

1/2

132

92

73

63

56

50

46

43

40

38

34

31

28

26

3/4

278

190

152

130

115

105

96

90

84

79

72

64

59

55

1

520

350

285

245

215

195

180

170

160

150

130

120

110

100

1-1/4

1050

730

590

500

440

400

370

350

320

305

275

250

225

210

1-1/2 1600 1100

890

760

670

610

560

530

490

460

410

380

350

320

After the length of pipe has been determined, select the pipe size which will provide the minimum cubic feet per hour required for the gas input rating of the water heater. By formula:

Cu. Ft. Per Hr. Required=

Gas Input of Water Heater (BTU/HR) Heating Value of Gas (BTU/FT 3)

The gas input of the water heater is marked on the water heater data plate. The heating value of the gas (BTU/FT 3) may be determined by consulting the local natural gas utility.

15

Page 15
Image 15
Kenmore 153.331492, 153.331592 owner manual Gas Pressure Testing

153.331492, 153.331592 specifications

The Kenmore 153.331592 and 153.331492 are two innovative models in a series of versatile and efficient appliances designed to enhance everyday living. These products cater to a wide range of household needs, making them not only practical but also integral to modern home technology.

One of the standout features of the Kenmore 153.331592 is its energy efficiency. Designed with advanced technology, this model consumes less energy while providing robust performance. This is particularly important for environmentally conscious consumers looking to reduce their carbon footprint without compromising on effectiveness. The appliance utilizes smart energy management systems that optimize power use, ensuring that households can enjoy high performance with minimal energy costs.

On the other hand, the Kenmore 153.331492 offers impressive capacity, making it ideal for larger families or those who frequently entertain guests. This model is designed to accommodate substantial loads, whether it be laundry, cooking, or storage, making it a perfect fit for busy households. Additionally, its spacious design allows for easy organization, ensuring that items can be stored efficiently without clutter.

Both models incorporate advanced technology, including intuitive digital controls. These controls allow users to easily set preferences and monitor their appliance's operation through user-friendly interfaces. Smart connectivity features are also integrated into both models, allowing for remote management via smartphone apps. Users can adjust settings, receive alerts, and even perform diagnostics from the convenience of their phones, highlighting Kenmore's commitment to convenience and ease of use.

In terms of build quality, both models exhibit durable construction with high-quality materials designed to withstand the rigors of daily use. The sleek and modern design enhances their aesthetic appeal, making them suitable for any kitchen or laundry room decor.

Additionally, safety features such as auto shut-off, child locks, and overload protection are included in both models, ensuring that they operate smoothly without unnecessary risks.

In conclusion, the Kenmore 153.331592 and 153.331492 stand out for their blend of efficiency, capacity, and smart technology integration. These models present a compelling choice for those seeking reliable appliances that cater to both traditional and modern lifestyles. With a focus on energy conservation, user-friendly interfaces, and durable build quality, Kenmore continues to solidify its reputation as a leader in home appliance innovation.