Installation Instructions
Installation Checklist
BEFORE LIGHTING THE PILOT:
Check the gas lines for leaks.
a. Use a soapy water solution• DO NOT test for gas leaks
(cont'd)
VENT PIPE TO
OUTDOORS
OR CHIMNEY
usinga match or open flame•
b. Brush the soapy water solution on all gas pipes, joints and fittings•
c. Check for bubbling soap. This means you have a leak.
t
HOT
SHUTOFF VALVE
Turn'OFF gas andmake the necessary repairs. d. Recheck for leaks.
e. Rinse offsoapy solution and wipe dry.
Is the new
and piped to an adequate drain? See
•Are the cold and hot water lines connected to the water
heater correctly? See "Water Piping" instructions in the "Installation Instructions" section.
•Is the water heater completely filled with water? See "Filling"
• | , | • | ++ | , | . | _ | , |
instructions | in the | Installation | Instrucnons |
| section. |
•Will a water leak damage anything? See the "Facts to Consider About the Location" section.
_.COLD
UNION
DRAFT HOOD
GAS SUPPLY | PRESSURE | |
+ | ||
RELIEF VALVE | ||
| ||
SHUTOFF |
| |
VALVE | (Do not cap or plug I |
•Is there proper clearance between the water heater and any-
thing that m!ght catch fire? See the "Facts to Consider About the Location section.
•Do you have adequate ventilation so that the water heater
will operate properly? See "Combustion Air and Ventilation" in the "Installation Instructions" section.
•Is the draft hood vent piping properly secured? See "Venting"
lnsrrtlCtlons | Ill the | Installation | Instructions | section. |
•Is there proper clearance between the vent pipe and anything that might catch on fire? See "Venting" instructions in the "Installation Instructions" section.
•Is the vent pipe properly sloped and does the vent terminate
outdoors? See "Venting" instructions in the "Installation Instructions" section.
Do you need to call your gas company to check the gas pipe and its hookup?
6" AIR GAP
DRAIN VALVE | FLOOR DRAIN |
7®
I
tJak_
"7 '2
,,..,_,_'_ | ,_.._ %_"_lt |
| |
I | I | I |
|
f,Ai | we. | w_ | W_ |
MODEL RATING PLATE