Kenmore 153.332319, 153.332419, 153.332463, 153.332363, 153.332161 Safety Precautions, Awarning

Models: 153.332319 153.332363 153.332419 153.332111 153.332161 153.332463 153.332563

1 28
Download 28 pages 55.15 Kb
Page 3
Image 3
Safety Precautions

Safety Precautions

_WARNING

A gas water heater cannot operate properly without the correct amount of air for combustion. Do not install in a

confined area such a closet, unless you provide air as shown in the "Facts to Consider About the Location" sec-

tion. Never obstruct the flow of ventilation air. If you have any doubts or questions at all, call your gas company.

Failure to provide the proper amount of combustion air can result in a fire or explosion and can cause DEATH,

SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.

_,WARNING

This water heater must not be installed directly on car- peting. Carpeting must be protected by a metal or wood panel beneath the appliance extending beyond the full

width and depth of the appliance by at least 3 inches (76.2mm) in any direction, or if the appliance is installed

in an alcove or closet, the entire floor must be covered by

the panel. Failure to heed this warning may result in a fire hazard.

AWARNING

HOTTER WATER CAN SCALD: Water heaters are intended to produce hot water. Water heated to a tem- perature which will satisfy clothes washing, dish washing, and other sanitizing needs can scald and permanently injure you upon contact. Some people are more likely to be permanently injured by hot water than others. These include the elderly, children, the infirm, or physicallylmen- tally handicapped. If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap, then you must take special precautions. In addi- tion to using the lowest possible temperature setting that satisfies your hot water needs, a means such as a mixing valve, should be used at the hot water taps used by these people or at the water heater. Hixing valves are available

at plumbing supply or hardware stores. Follow manufac- turers instructions for installation of the valves. Before

changing the factory setting on the thermostat, read the "Temperature Regulation" section in this manual.

AWARNING

Soot build-up indicates a problem that requires correc- tion before further use. Turn "OFF" gas to water heater and leave "OFF" until repairs are made, because failure to correct the cause of the sooting can result in a fire or explosion causing DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.

AWARNING

VENT DAMPERS - Any vent damper, whether it is operat- ed thermally or otherwise must be removed if its use inhibits proper drafting of the water heater.

Thermally Operated Vent Dampers: Gas-fired water heaters having thermal efficiency in excess of 80% may produce a relatively low flue gas temperature. Such tem- peratures may not be high enough to properly open ther- mally operated vent dampers. This would cause spillage of flue gases and may cause carbon monoxide poisoning.

Vent dampers must bear evidence of certification as com-

plying with the latest edition of American National Standard ANSI Z21.68 (ANSI Z2h66 & 67, respectively,

cover electrically and mechanically actuated vent dampers). Before installation of any vent damper, consult

your local Sears Service Center or the gas utility for fur- ther information.

AWARNING

The appliance and its individual shutoff valve must be dis- connected from the gas supply piping system during any pressure testing of the gas system at test pressures in excess of ½ pound per square inch (3.SkPa).

The appliance must be isolated from the gas supply pip- ing system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping sys- tem at test pressures equal or less than Y2 pound per square inch (3,5kPa).

AWARNING

BEFORE LIGHTING [PROPANE (L.R) GAS WATER

HEATERS]: Propane (L.R) gas is heavier than air. Should there be a leak in the system, the gas will settle near the

ground. Basements, crawl spaces, skirted areas under mobile homes (even when ventilated), closets and areas below ground level will serve as pockets for the accumula-

tion of this gas. Before attempting to light or relight the water heater's pilot or turning on a nearby electrical light switch, be absolutely sure there is no accumulated gas in :he area. Search for odor of gas by sniffing at ground level in the vicinity of the appliance. If odor is detected, follow steps indicated at "For Your Safety" on the cover page of this manual then leave the premises.

_ WARNING

Chemical vapor corrosion of the flue and vent system may occur if air for combustion contains certain chemical vapors. Spray can propellants, cleaning solvents, refrigera-

tor and air conditioner refrigerants, swimming pool chemicals, calcium and sodium chloride, waxes, bleach, and process chemicals are typical compounds which are _otentially corrosive.

AWARNING

Obstructed or deteriorated vent systems may present a

serious heath r sk or asphyx at on.

Safety Precautions continued on page 4.