Installation Instructions (cont'd)
Water Piping
AWARNING
HOTTER WATER CAN SCALD: Water heaters are intended to _reduce hot water. Water heated to a temperature which will satisfyclothes washing,dish washing,and other sanitizing needs can scald and permanently injure you upon contact. Some peo- fie are more likely to be permanently injured by hot water than others. These include the elderly, children,the infirm, or physical. lylmentally handicapped.If anyone usinghot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap, then _u must take special precautions.In addition to usingthe lowest )ossibletemperature setting that satisfiesyour hot water needs, a means such as a mixing valve, shouldbe usedat the hot water taps used by these people or at the water heater. Mixing valves are available at plumbing supplyor hardware stores. Follow man- ufacturers instructions for installation of the valves. Before changing the factory setting on the thermostat, read the "Temperature Regulation" section in this manual.
|
| AWARNING |
| ] |
This water | heater_connected | to | any | |
heating | systems or component(s) | used with a | ||
potable | water | heating appliance. |
| ] |
Look at the top cover of the water heater. The cold water
inlet is marked cold. Put two or three turns of teflon tape
around the threaded end of the
NOTE: This water heater is super insulated to minimize heat loss from the tank. Further reduction in heat loss
can be accomplished by insulating the hot water lines from the water heater.
INSTALLATION COMPLETED | USING | ||
SEARS INSTALLATION | KIT |
| |
|
| SHUTOFF | |
CONNECTORS |
|
|
|
HOT |
| [_E |
|
FLEXIBLE WATER |
|
| |
\'- | COLD INLET | ||
OUTLET |
|
| |
TO HOUSE |
|
| WATER LINE |
THREADED TO | THREADED TO | ||
SWEAT COUPLING | SWEAT COUPLING |
I | "WARN,.G |
| 1 |
Toxic chemicals | suc_reatment | of boilers/ |
|
or | water heating appliances | shall never |
|
be introduced | into a potable water heating | system, | / |
If a water heater is installed in a closed water supply system; such as one having a
shall be provided to control thermal expansion. Contact the
local utility or local Sears Service Center on how to control this situation.
NOTE: To _protect against untimely corrosion of hot and cold water tlttings, it is strongly recommended that
The illustration shows the attachment of the water piping to the water heater. The water heater is equipped with 5a inch water
con Ilections,
_314"THREADED | |
NIPPLE | NIPPLE |
40T | COL |
I_
PRESSURE
RELIEF VALVE
<- | DISCHARGE |
[] | PIPE (Do not cap |
or plug) |
NOTE: If using copper tubing, solder tubing to an adapter before attaching the adapter to the cold water inlet connec- tion. Do not solder the cold water supply line direcdy to the
cold water inlet. It will harm the dip tube and damage the tank.
•Look at the top cover of the water heater. The water outlet is marked hot. Put two or three turns o teflon tape around the
threaded end of the
tors, connect the hot water pipe to the hot water outlet on the water heater.
6" AIR GAP
FLOOR DRAIN
11