TheseguidelinesshouldbeusedbyaqualifiedserviceagentCallSearsServiceat1.-8004-MY-HOME(1-800-469-4663) forassistanceInformtheassociatethatthisisa."Flammable Vapor Ignition Resistant" Product.

 

Improperly sealed, hot or cold supply connection,

WATER LEAKS

relief valve, drain valve, or thermostat threads.

 

Leakage

 

from

other

appliances or water lines.

 

Condensation

of flue

products.

 

Thermal expansion in closed water system.

LEAKING T&P VALVE

Improperly

seated valve.

 

 

High sulfate or mineral content in water supply.

SMELLY ODORS

 

 

 

 

 

 

 

 

Bacteria

 

in water supply.

 

 

Gas control knob not positioned correctly.

 

Main gas

supply off.

 

 

 

Igniter tip more than 1/8" from pilot hood.

 

Thermoceuple

malfunction.

 

Thermoceuple

TCO malfunction.

 

Melted insulation on ignitor wire or shorting

PILOT WILL NOT LIGHT

of ignitor

 

wire.

 

 

 

 

 

 

 

 

 

High ambient

room temperature.

 

Wire disconnected from spark ignitor.

 

Broken electrode or electrical wire.

 

Piezo Ignitor generator fails to operate or

 

malfunctions.

 

 

 

 

 

Thermoceuple

TCO malfunction.

 

High ambient

room temperature.

BURNERWlLL NOT

Dirty or clogged air intake

screen.

STAY LIT

Flame arrestor

openings

blocked.

 

Defective

 

Gas

Control.

 

 

Dirty pilot

burner.

 

 

 

Dirty or clogged air intake screen.

PILOT OUTAGE

Thermoceuple

tip is not in contact with pilot flame.

 

Thermoceuple

malfunction.

 

Thermoceuple

TCO malfunction.

 

Defective

 

Gas

Control.

 

 

Heater not lit or thermostat not on.

 

Thermostat

set

too low.

 

 

Heater undersized.

 

 

NOTENOUGH

Low gas

 

pressure.

 

 

HOTWATER

Incoming

 

water

is unusually cold.

 

Leaking hot water pipes or fixtures.

 

High temperature limit switch activated.

WATER TOO HOT

Thermostat

set too high.

 

WATER HEATER SOUNDS

Condensation dripping on burner.

SIZZLING - RUMBLING

Sediment

or calcium in bottom of heater tank.

SOOTING

Improper

 

combustion.

 

 

 

Lack of

supply

air.

 

 

VENTGASODORS

Improperly

installed vent piping.

Downdraft.

 

 

 

 

 

 

 

 

 

Poor combustion.

Tighten threaded connections.

Inspect other appliances near water heater. Refer to CONDENSATION.

Install thermal expansion tank (DO NOT plug T&P valve). Check relief valve for proper operation

(DO NOT plug T&P valve).

Drain and flush heater thoroughly, then refill.

Chlorinate or aerate water supply.

Refer to LIGHTING INSTRUCTIONS.

Turn on main gas shutoff valve.

Adjust ignitor tip.

Replace pilot assembly.

Replace pilot assembly.

Contact Sears Service to determine cause.

Contact Sears Service to determine cause.

Reconnect wire connector to spark ignitor. Replace pilot assembly.

Replace Piezo Ignitor generator.

Replace pilot assembly. Contact a service agency to determine cause.

Clean and reinstall air intake screen. Contact Sears Service to determine cause.

Replace Gas Control.

Clean pilot assembly.

Clean and reinstall air intake screen.

Insert thermocouple correctly.

Replace pilot assembly.

Replace pilot assembly.

Replace Gas Control.

Refer to LIGHTING INSTRUCTIONS.

RefertoTEMPERATURE REGULATION.

Reduce hot water use.

Contact your gas supplier.

Allow more time for heater to re-heat. Have plumber check and repair leaks. Contact Sears Service to

determine cause.

Refer toTEMPERATURE REGULATION.

Refer toCONDENSATION.

Clean sediment from tank. Refer to DRAINING instructions in Maintenance section of manual.

No adjustment available. Contact Sears Service to determine cause.

Contact Sears Service to determine cause.

26

Page 26
Image 26
Kenmore 153.33616 owner manual Leaking T&P Valve