Installation Instructions (cont'd)
Temperature-Pressure Relief Valve
a, WARNING
At the time of manufacturethis water heater was provided with a
by a nationally recognizedtesting laboratory that maintains periodicinspectionof productionof listedequipmentor mate- rials, as meeting the requirements for Relief Valves and _utomatic GasShutoffDevicesfor Hot Water SupplySystems, md the latest edition of ANSI Z21.22 and the code require. _ents of ASME. If replaced, the valvemust meet the require- _ents of localcodes,but not lessthan a combinationtempera-
pureand pressurerelief valvecertifiedas meetingthe require- mentsfor ReliefValvesand Automatic GasShutoffDevicesfor
Hot Water SupplySystems,ANSI Z21.22 bya nationallyrecog- nizedtestinglaboratory that maintains periodic inspectionof pTreductionof listedequipmentor materials.
he valvemust be marked with a maximum set pressurenot to exceed the marked hydrostaticworking pressureof the water heater (150 Ibsdsq,in.) and a dischargecapacitynot less thanthe water heater input rate as shown on the modelrating plate. (Electric heaters- watts dividedby 1000x 3415 equal
BTU/Hr. rate.) .
Yourlocaljurisdictionalauthor_y,while mandatingthe useof a
and ASME, may require a valvemodel differentfrom the one furnishedwith the water heater.
Compliancewith suchlocalrequirementsmust be satisfiedby
the installeror end userof the water heater with a locallyp,re- scribed
nated openingin the water heater in placeof the factory fur. nishedvalve,
Forsafeoperationof the water heater,the relief valvemustnot beremoved from it_ designatedopeningor plugged,
chargewill exit onlywithin 6 inchesabove, or at any distance )elow the structuralfloor.Be certainthat no contact is made
with any liveelectricalpart.The dischargeopeningmust not be blockedor reduced in size underany circumstancesExcessive.
leng_, over 30 feet, or useof more than fourelbowscancause restriction and reducethe dischargecapacityofthe valve.
qo valveor other obstructionis to be placedbetweenthe relief ralveandthe tank. Do not connecttubingdirectlyto discharge
Iraln unlessa 6" air gapisprovided,To preventbodilyinjury,haz-
,'dto life,or propertydamage,the relief valvemustbe allowed to dischargewater in quantitiesshouldcircumstancesdemand.If
the dischargepipeis not connectedto a drain or other suitable means,the water flowmaycausepropertydamage.
•e DischargePipe:
Must not be smallerin sizethan the outlet pipesize of the valve,or haveany reducingcouplingsor other restrictions.
Mustnot be pluggedor Mocked.
Mustbe of materiallistedfor hot water distribution.
Must be installedso as to allow completedrainageof beth the
pipe.
Mustterminate at anadequatedrain,
Must not haveanyvalvebetweenthe relief valveand tank.
AWARNING
The
!ensurethat (I) no one is in front of or aroundthe outlet o the
If after manual.lyoperating the valve, it fails,to completely reset and continuesto release water, immediately closethe
cold water inlet to the water heater, follow the draining
instructions, and replace the
HOT | SHUTOFF COLD |
| VALVE |
PRESSURE
RELIEF VALVE
(Do not cap or plug)
[]
6" AIR GAP
RELIEFVALVEOPENING
At the time of manufacture,this waterheaterwasprovidedwitha combinationtem-
YourIota;jurisdictionalauthority,whilemandatingthe useof a
Compliancewithsuchlocal_luirements mustbesatisfiedby theinstalleror enduser of the waterheaterwitha
inthe designatedopeningin thewaterheater.