Kenmore 153.337962, 153.337863 Installation Instructions, contd, Installation Checklist

Models: 153.337363 153.337463 153.337563 153.337863 153.337214 153.337414 153.337614 153.337962 153.337163 153.337663 153.337763 153.337514 153.337963 153.337114

1 36
Download 36 pages 5.21 Kb
Page 16
Image 16
Installation Instructions

Installation Instructions

Installation Checklist

BEFORE LIGHTING THE PILOT:

Check the gas lines for leaks.

a.Use a soapy water solution. DO NOT test for gas leaks usinga match or open flame.

b.Brush the soapy water solution on all gas pipes, joints and fittings.

c.Check for bubbling soap. This means you have a leak. Turn "OFF" gas andmake the necessary repairs.

d.Recheck for leaks.

e.Rinse offsoapy solution and wipe dry.

(cont'd)

VENT PIPE TO UNION

OUTDOORS

OR CHIMNEY

SHUTOFF VALVE

Is the new temperature-pressure

relief valve properly installed

 

and piped to an adequate dram. See Temperature-Preasure

 

Relief Valve" section.

 

Are the cold and hot water lines connected to the water

 

heater correctly? See "Water Piping" instructions in the

 

"Installation Instructions" section.

Is the water heatercompletely

filled with water? See "Filling"

HOT

COLD

DRAFT HOOD

 

instructions in

the

Installation Instructions" section.

Will

a water

leak

damage anything? See

the

"Facts to

 

Consider About the Location" section.

 

 

Is there proper

dearanee between the water

heater

and any-

 

thing

that might catch fire? See the "Facts to

Consider About

GAS SUPPLY

PRESSURE

RELIEF VALVE

DISCHARGE PIPE (Do not cap or plug)

 

the Location" section.

 

 

• Do you have adequate ventilation

so that the water heater

 

will operate properly? See "Combustion Air and Ventilation"

 

in the Facts to Consider About the Location" section.

Is the draft hood vent piping properly secured? See "Venting"

 

instructions in the "Installation Instructions" section.

Is there proper clearance betwe,en the vent pipe and anything

 

that might catch on fire? See Venting instructions in the

 

"Installation

Instructions"

section.

 

Is the vent

pipe properly

sloped and

does the vent terminate

outdoors. See

_

, . .

.

.

the

¢¢

.

 

Venting instructions

m

 

Installation

Instructions" section.

Do you need to call your gas company to check the gas pipe and its hookup?

SHUTOFF VALVE

TEE

DRIP LEG (Sediment

trap) PIPE CAP

6" AIR GAP

DRAIN VALVE

FLOOR DRAIN

UOTOVATEEL NUMBER! Wllm _llm" _

 

 

 

 

 

ANS Z21_10

 

 

P0R

_

 

FIEGO_Y

 

_

 

 

 

I

 

I

 

I

 

 

 

BTm4R

 

 

 

 

 

 

 

Is0

]

.

]

.

]

.o

 

pJkJ

 

 

 

 

 

 

MODEL RATING PLATE

16

Page 16
Image 16
Kenmore 153.337962, 153.337863, 153.337963, 153.337463, 153.337414 Installation Instructions, contd, Installation Checklist