Venting (cont'd)

Installation Instructions

Venting (cont'd)

All vent gases must be completely vented to the outdoors of the

structure (dwelling). Installonly the draft hood provided with the new water heater and no other draf_ hood.

Vent pipes must be secured at each joint with sheet metal screws.

TO

CHIMNEY

RISE PER LINEAR

FOOT

!

VENT PIPE INSTALLATION

There must be a minimum of 6" clearance between single wall vent pipe and any combustible material. Fill and seal any clear-

ance between single wall vent pipe and combustible material with mortar mix, cement, or other noncombustible substance.

For other than single wall, follow vent pipe manufacturer's clear- ance specifications. To insure _"tight fit of the vent pipe in a brick chimney, seal around the vent pipe with mortar mix cement.

AWARNING

Failureto haverequired clearancesbetween vent pipingand combustiblematerial will result in a Erehazard.

AWARNING

Be surevent pipeisproperly connectedto preventescapeof

dangerousilue gaseswh chcou d causedeadlyasphyxation.

AWARNING

Chemical vapor corrosionof the flue and vent system may occurif air for combustioncontainscertain chemicalvapors. Spraycan propellants,cleaningsolvents,refrigerator and air

conditionerrefrigerants, swimming pool chemicals,calcium and sodiumchloride,waxes,bleach,and processchemicalsare

typicalcompoundswhichare potentiallycorrosive.

(cont'd)

Gas Piping

AWARNING

Make sure the gas supplied is the same type listed on the model rating plate. The inlet gas pressuremust not exceed 10.5in.water column(2.6kPa) for natural gasor 13 in.water column (3.2kPa) for propane(I-R) gas.The minimum inlet

gas pressurelisted on the model rating plate is for the pur. poseof input adjustment.

AWARNING

I

If the gascontrolvalveis subjectedto pressuresexceeding_AI pound per squareinch(3.5kPa), the damage to the gascon-

tro valvecouldresult n a Ereor exploson from eakinggas.

AWARNING[ If the main gasline shutoffserving all gasappliancesis used,[ also torn "off" the gasat each appliance.Leaveall gasappli- ancesshutoff until the water heater installations comp ete.

A gas line of sufficient size must be run to the water heater. Consult the latest edition of National Fuel Gas Code ANSI

Z223.1, also referred to as NFPA 54 and the gas company con- cerning pipe size.

There must be:

A readily accessiblemanual shut off valve in the gas supply line serving the water heater, and

A drip leg (sediment trap) ahead of the gas control valve to hdp

prevent dirt and foreign materials from entering the gas control

valve,

A flexible gas connector or a ground joint union between the shutoffvalve and control valve to permit servicing of the unit.

Be sure to check all the gas piping for leaks before lighting the water heater. Use a soapy water solution, not a match or open flame. Rinse offsoapy solution and wipe dry.

t .

Standard Models are for installation up to 3,300 feet above sea

level.

High Altitude Models are for installation from 3,300 to 5,500 feet above sea level.

Ifa standard model is installed above 3,300 feet or a high altitude model is installed above 5,500 feet, the input rating must be reduced at the rate of 4 percent for each 1,000 feet above sea level.

Contact your local Sears Service Center or gas utility for further information.

AWARNING

The appliance and its gas connection must be leak tested before p acingthe app ance n operation.