Forproperdrafthoodattachment,thedrafthoodlegsmay

Toinsureproperventingofthisgas-firedwaterheater,the correctventpipediametermustbeutilized,Anyadditionsor deletionsofothergasappliancesonacommonventwiththis waterheatermayadverselyaffecttheoperationofthewater heater.Consultyourgassupplierif anysuchchangesare planned.

Forproperventingin certaininstallations,largerdiameter ventpipemaybenecessary,ConsultyourlocalSearsService Centerorgassupplierto aidyouindeterminingtheproper ventingforyourwaterheaterfromtheventtablesinthecurrent editionoftheNationalFuelGasCodeANStZ223,1/NFPA54,

Periodicallychecktheventingsystemforsignsofobstruction ordeteriorationandreplaceifneeded,

Thecombustionandventilationairflowmustnotbeobstructed,

Thewaterheaterwithdrafthoodinstalledmustbeconnected toa chimneyorlistedventpipesystem,whichterminatesto theoutdoors,Neveroperatethewaterheaterunlessitisvented totheoutdoorsandhasadequateairsupplytoavoidrisksof improperoperation,explosionorasphyxiation,

Forproperdrafthoodattachment,thedrafthoodlegsmay

beangledslightlyinward,

Placethedrafthoodlegsinthereceivingholesonthetopof thewaterheaterThelegswillsnapintheholestogivea. tightfit.Securetwolegstotopwithsheetmetalscrews,

Placetheventpipeoverthedrafthood,Withtheventpipein

position,drillasmallholethroughboththeventpipeand

drafthood,Securethemtogetherwithasheetmetalscrew,

SeeFigure17.

DRAFT HOOD

_

VENT_L

$

so.% I" I e.ArTHO00

VENT TO OUTDOORS

DRAFT HOOD

FIGURE17.

Obstructed or deteriorated vent systems may present serious health risk or asphyxiation.

The vent pipe from the water heater must be no less than the diameter of the draft hood outlet on the water heater and must

slope upward at least 1/4 inch per linear foot (21 mm per meter).

See Figure 18,

CHIMNEY

FIGURE18.

All vent gases must be completely vented to the outdoors of the structure (dwelling). Install only the draft hood provided with the new water heater and no other draft hoed.

Vent pipes must be secured at each joint with sheet metal screws,

There must be a minimum of 6 inches (153 mm) clearance between single wall vent pipe and any combustible material. Fill and seal any clearance between single wall vent pipe and

combustible material with mortar mix, cement, or other noncombustible substance. For other than single wall, follow vent pipe manufacturer's clearance specifications. To insure a tight fit of the vent pipe in a brick chimney, seal around the vent pipe with mortar mix cement.

Failure to have required clearances between vent piping and combustible material will result in a fire hazard.

Be sure vent pipe is propedy connected to prevent escape of dangerous flue gases which could cause deadly asphyxiation.

Flue gases may escape if vent p_peis not connected

Do not store corrosive chemicals in vicini_'of water heater.

Chemical corrosion of flue and vent system can cause serious injury or death.

Contact a qualified installer or service agency

Breathing carbon monoxide can cause brain damage

or death Always read and Lmderstand instruction manual

Chemical vapor corrosion of the flue and vent system may occur if air for combustion contains certain chemical vapors. Spray can propellants, cleaning solvents, refrigerator and air conditioner refrigerants, swimming pool chemicals, calcium and sodium chloride, waxes, bleach and process chemicals are typical compounds which are potentially corrosive.

Gas Piping

Fire and Explosion Hazard

Do not use water heater with any gas other than the gas shown on the rating plate

,Excessve pressure to gas control valve can cause serious injury or death

,Turn off gas lines during installation

,Contact qualified installer or service agency