GROUND JO{NT

 

UNION

GAS CONTROL

{OPTIONAL)

VALVE

3" MIN.

{SEDIMENT

TRAP)

(76.2 m _)_[-

DR{P

LEG

CAP

FIGURE 19. GAS PIPING WITH FLEXIBLE CONNECTOR.

A sediment trap shall be installed as close to the inlet of the water heater as practical at the time of water heater installation. The sediment trap shall be either a tee fitting with a capped nipple in the bottom outlet or other device recognized as an

effective sediment trap. If a tee fitting is used, it shall be installed in conformance with one of the methods of installation, shown in Figures 19 and 20.

GROUND JOJNT'_

_ B L A_lk

(OPTIONAL)

BLACK rlr_PiPE_

UNION

CONTROL

VALVE

3" MIN,

(76,2 m

GAS

CAP

FIGURE 20. GAS PIPING WITH ALL

BLACK IRON PIPE TO GAS CONTROL.

17

Page 17
Image 17
Kenmore 153.339210 HA, 153.33996, 153.33956, 153.33976, 153.33926 GAS Piping with ALL Black Iron Pipe to GAS Control