PRODUCT DATA SHEETS
Base Grille Water Filtration System Model
|
|
|
| 1 |
|
|
|
|
|
|
|
| |
|
|
|
|
| 42 for the reduction of Chlorine (Class I) Taste and Odor and against |
|
|
| |||||
|
|
|
| I Tested and certified by NSF International against ANSI/NSF Standard |
|
| |||||||
|
|
|
|
| ANSI/NSF Standard 53 for the reduction of Lead, Cysts and Turbidity. |
|
| ||||||
|
| Capacity: 250 Gallons (946 Liters) |
|
|
|
|
|
|
| ||||
|
| Service Flow Rate: 0.5 GPM (1.89 L/min.) @60 psi. |
|
|
|
|
|
|
| ||||
Substance | Reduction | U.S. EPA | Average | Maximum | Average | Minimum | % | Average | % | NSF Test | |||
Aesthetic | Effects | MCL |
| Influent | Effluent | Effluent | Reduction |
| Reduction |
| Number | ||
Chlorine Taste/Odor | N/A |
| 1.9 mg/L | N/A | 0,04 mg/L | N/A |
| 97.9% |
| 994707 | |||
Particulate |
| N/A |
| 610,000/mL* | N/A | 154/mL | N/A |
| 99.97% |
| 994711 | ||
Contaminant | U.S. EPA | Average | Maximum | Average | Minimum | % | Average | % | NSF Test | ||||
Reduction |
| MCL |
| Influent | Effluent | Effluent | Reduction |
| Reduction |
| Number | ||
Cyst |
| 99.95%** | 89,250/mL* | 6/mL | 2,3/mL |
| 99,993% |
| 99.997% |
| 994710 | ||
Turbidity |
| 0.5 NTU | 29 NTU | 0.1 NTU | 0,09 NTU | 99,5% |
| 99.69% |
| 994710 | |||
Lead: @pH 6.5 | 0.015 | mg/L | 0.16 | mg/L*** | 0.001 mg/L | 0.001 | mg/L | 99.4% |
| 99.4% |
| 994708 | |
Lead: @pH 6.5 | 0.015 | mg/L | 0.16 | mg/L*** | 0.002 mg/L | 0.001 | mg/L | 98.8% |
| 99.4% |
| 994709 | |
Base Grille Water Filtration System Model |
|
|
|
|
|
|
|
|
| 1 |
|
|
|
|
|
|
|
| |
|
|
|
|
| 42 for the reduction of Chlorine (Class I) Taste and Odor and against |
|
|
| |||||
|
|
|
| I Tested and certified by NSF International against ANSI/NSF Standard |
|
| |||||||
|
|
|
|
| ANSI/NSF Standard 53 for the reduction of Lead, Cysts and Turbidity. |
|
| ||||||
|
| Capacity: 400 Gallons (1514 Liters) |
|
|
|
|
|
|
| ||||
|
| Service Flow Rate: 0.5 GPM (1.89 L/min.) @60 psi. |
|
|
|
|
|
|
| ||||
Substance | Reduction | U.S. EPA | Average | Maximum | Average | Minimum | % | Average | % | NSF Test | |||
Aesthetic | Effects | MCL |
| Influent | Effluent | Effluent | Reduction |
| Reduction | Number | |||
Chlorine Taste/Odor | N/A |
| 2.0 | mg/L | N/A | 0.04 mg/L | N/A |
| 98% |
| 994707 | ||
Particulate |
| N/A |
| 610,000/mL* | N/A | 154/mL | N/A |
| 99% |
| 994711 | ||
Contaminant | U.S. EPA | Average | Maximum | Average | Minimum | % | Average | % | NSF Test | ||||
Reduction |
| MCL |
| Influent | Effluent | Effluent | Reduction |
| Reduction | Number | |||
Cyst |
| 99.95%** | 89,250/mL* | 6/mL | 2.3/mL |
| 99.993% |
| 99.997% |
| 994710 | ||
Turbidity |
| 0.5 NTU | 29 NTU | 0.12 NTU | 0.09 NTU | 99.59% |
| 99.69% |
| 994710 | |||
Lead: @pH 6.5 | 0.015 | mg/L | 0.16 | mg/L*** | 0.001 mg/L | 0.001 | mg/L | 99.4% |
| 99.4% |
| 994708 | |
Lead: @pH 6.5 | 0.015 | mg/L | 0.16 | mg/L*** | 0.002 mg/L | 0.001 | mg/L | 98.8% |
| 99.4% |
| 994709 |
It is essential that operational, | maintenance, | and filter | • Refer to the "Warranty" | section for the Manufacturer's limited | ||||
replacement | requirements be carried | out for | the product to | warranty. |
| |||
perform as advertised. |
|
|
|
|
|
| ||
Model | cartridge | at least every |
| Application Guidelines/Water Supply Parameters | ||||
months. Use replacement cartridge NLC 250, part# 9902. | Water | Supply | City or Well | |||||
2000 suggested retail price of $39.95 U.S.A./S49.95 Canada. | ||||||||
Water | Pressure | 30 - 120 psi (207 - 827 kPa) | ||||||
Model | ||||||||
Water | Temperature | 33 ° - 100°F (0.6 ° - 37.8 ° C) | ||||||
amount of water that passes through the filter and alerts you | ||||||||
|
|
| ||||||
to replace the filter. When 90% of the filter's rated life is used, |
|
|
| |||||
the filter indicator light changes from green to yellow. When |
|
|
| |||||
100% of the filter's rated life is used, the filter indicator light |
|
|
| |||||
changes from yellow to red, and it is recommended that you |
|
|
| |||||
replace the filter. Use replacement cartridge LC400, part# |
|
|
| |||||
9902. 2000 | suggested retail | price of $39.95 | U.S.A./S49.95 |
|
|
| ||
Canada. |
|
|
|
|
|
|
|
•The product is for cold water use only.
•Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
•Refer to the "Assistance or Service" section for the Manufacturer's name, address and telephone number.
*Test requirement is at least 100,000 particles/ml of AC Fine Test Dust. **Cyst performance is % reduction based on NSF Standard 53. ***Test
requirement is 0.15 mg/L _+10%. These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions. ® NSF is a registered trademark of NSF International.
24