Base Grille Water Filtration System Model WF-NLC250/NLC250

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

42 for the reduction of Chlorine (Class I) Taste and Odor and against

 

 

 

 

 

 

 

I Tested and certified by NSF International against ANSI/NSF Standard

 

 

 

 

 

 

 

ANSI/NSF Standard 53 for the reduction of Lead, Cysts and Turbidity.

 

 

 

 

Capacity: 250 Gallons (946 Liters)

 

 

 

 

 

 

 

 

 

Service Flow Rate: 0.5 GPM (1.89 L/min.) @60 psi.

 

 

 

 

 

 

 

Substance

Reduction

U.S. EPA

Average

Maximum

Average

Minimum

%

Average

%

NSF Test

Aesthetic

Effects

MCL

 

Influent

Effluent

Effluent

Reduction

 

Reduction

 

Number

Chlorine Taste/Odor

N/A

 

1.9 mg/L

N/A

0,04 mg/L

N/A

 

97.9%

 

994707

Particulate

 

N/A

 

610,000/mL*

N/A

154/mL

N/A

 

99.97%

 

994711

Contaminant

U.S. EPA

Average

Maximum

Average

Minimum

%

Average

%

NSF Test

Reduction

 

MCL

 

Influent

Effluent

Effluent

Reduction

 

Reduction

 

Number

Cyst

 

99.95%**

89,250/mL*

6/mL

2,3/mL

 

99,993%

 

99.997%

 

994710

Turbidity

 

0.5 NTU

29 NTU

0.1 NTU

0,09 NTU

99,5%

 

99.69%

 

994710

Lead: @pH 6.5

0.015

mg/L

0.16

mg/L***

0.001 mg/L

0.001

mg/L

99.4%

 

99.4%

 

994708

Lead: @pH 6.5

0.015

mg/L

0.16

mg/L***

0.002 mg/L

0.001

mg/L

98.8%

 

99.4%

 

994709

Base Grille Water Filtration System Model WF-LC4OO/LC400

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

42 for the reduction of Chlorine (Class I) Taste and Odor and against

 

 

 

 

 

 

 

I Tested and certified by NSF International against ANSI/NSF Standard

 

 

 

 

 

 

 

ANSI/NSF Standard 53 for the reduction of Lead, Cysts and Turbidity.

 

 

 

 

Capacity: 400 Gallons (1514 Liters)

 

 

 

 

 

 

 

 

 

Service Flow Rate: 0.5 GPM (1.89 L/min.) @60 psi.

 

 

 

 

 

 

 

Substance

Reduction

U.S. EPA

Average

Maximum

Average

Minimum

%

Average

%

NSF Test

Aesthetic

Effects

MCL

 

Influent

Effluent

Effluent

Reduction

 

Reduction

Number

Chlorine Taste/Odor

N/A

 

2.0

mg/L

N/A

0.04 mg/L

N/A

 

98%

 

994707

Particulate

 

N/A

 

610,000/mL*

N/A

154/mL

N/A

 

99%

 

994711

Contaminant

U.S. EPA

Average

Maximum

Average

Minimum

%

Average

%

NSF Test

Reduction

 

MCL

 

Influent

Effluent

Effluent

Reduction

 

Reduction

Number

Cyst

 

99.95%**

89,250/mL*

6/mL

2.3/mL

 

99.993%

 

99.997%

 

994710

Turbidity

 

0.5 NTU

29 NTU

0.12 NTU

0.09 NTU

99.59%

 

99.69%

 

994710

Lead: @pH 6.5

0.015

mg/L

0.16

mg/L***

0.001 mg/L

0.001

mg/L

99.4%

 

99.4%

 

994708

Lead: @pH 6.5

0.015

mg/L

0.16

mg/L***

0.002 mg/L

0.001

mg/L

98.8%

 

99.4%

 

994709

It is essential that operational,

maintenance,

and filter

• Refer to the "Warranty"

section for the Manufacturer's limited

replacement

requirements be carried

out for

the product to

warranty.

 

perform as advertised.

 

 

 

 

 

 

Model WF-NLC250 Change

cartridge

at least every 6-9

 

Application Guidelines/Water Supply Parameters

months. Use replacement cartridge NLC 250, part# 9902.

Water

Supply

City or Well

2000 suggested retail price of $39.95 U.S.A./S49.95 Canada.

Water

Pressure

30 - 120 psi (207 - 827 kPa)

Model WF-LC400 The filter monitor system measures the

Water

Temperature

33 ° - 100°F (0.6 ° - 37.8 ° C)

amount of water that passes through the filter and alerts you

 

 

 

to replace the filter. When 90% of the filter's rated life is used,

 

 

 

the filter indicator light changes from green to yellow. When

 

 

 

100% of the filter's rated life is used, the filter indicator light

 

 

 

changes from yellow to red, and it is recommended that you

 

 

 

replace the filter. Use replacement cartridge LC400, part#

 

 

 

9902. 2000

suggested retail

price of $39.95

U.S.A./S49.95

 

 

 

Canada.

 

 

 

 

 

 

 

The product is for cold water use only.

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

Refer to the "Assistance or Service" section for the Manufacturer's name, address and telephone number.

*Test requirement is at least 100,000 particles/ml of AC Fine Test Dust. **Cyst performance is % reduction based on NSF Standard 53. ***Test

requirement is 0.15 mg/L _+10%. These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions. ® NSF is a registered trademark of NSF International.

24

Page 24
Image 24
Kenmore 2205960 manual Product Data Sheets