Base Grille Water Filtration System Model WF-NLC250/NLC250

Tested and certified by NSF International against ANSI/NSF Standard 42 for the reduction of Chlorine (Class I) Taste and Odor and against ANSI/NSF Standard 53 for the reduction of Lead, Cysts and Turbidity.

Capacity: 250 Gallons (946 Liters)

Service Flow Rate: 0.5 GPM (1.89 L/min.) @60 psi.

Substance

Reduction

U.S. EPA

Average

Maximum

Average

Minimum

%

Average

% NSF Test

Aesthetic

Effects

MCL

 

Influent

Effluent

Effluent

Reduction

 

Reduction

Number

Chlorine Taste/Odor

N/A

 

1.9 mg/L

N/A

0.04

mg/L

N/A

 

97.9%

 

994707

Particulate

 

N/A

 

610,000/mL*

N/A

154/mL

N/A

 

99.97%

 

994711

Contaminant

U.S. EPA

Average

Maximum

Average

Minimum

%

Average

% NSF Test

Reduction

 

MCL

 

Influent

Effluent

Effluent

Reduction

 

Reduction

Number

Cyst

 

99.95%**

89,250/mL*

6/mL

2.3/mL

99.993%

 

99.997%

 

994710

Turbidity

 

0.5 NTU

29 NTU

0.1 NTU

0.09

NTU

99.5%

 

99.69%

 

994710

Lead: @pH 6.5

0.015

mg/L

0.16 mg/L***

0.001mg/L

0.001

mg/L

99.4%

 

99.4%

 

994708

Lead: @pH 8.5

0.015

mg/L

0.16 mg/L***

0.002 mg/L

0.001

mg/L

98.8%

 

99.4%

 

994709

Base Grille Water Filtration System Model WF-LC400/LC400

Tested and certified by NSF International against ANSI/NSF Standard 42 for the reduction of Chlorine (Class I) Taste and Odor and against ANSI/NSF Standard 53 for the reduction of Lead, Cysts and Turbidity.

Capacity: 400 Gallons (1514 Liters)

Service Flow Rate: 0.5 GPM (1.89 L/min.) @60 psi.

Substance

Reduction

U.S. EPA

Average

Maximum

Average

Minimum

%

Average

%

NSF Test

Aesthetic

Effects

MCL

 

Infiuent

Effluent

Effluent

Reduction

 

Reduction

Number

Chlorine Taste/Odor

N/A

 

2.0 mg/L

N/A

0.04

mg/L

N/A

 

98%

 

994707

Particulate

 

N/A

 

610,000/mL*

N/A

154/mL

N/A

 

99%

 

994711

Contaminant

U.S. EPA

Average

Maximum

Average

Minimum

%

Average

%

NSF Test

Reduction

 

MCL

 

Infiuent

Effluent

Effluent

Reduction

 

Reduction

Number

Cyst

 

99.95%**

89,250/mL*

6/mL

2.3/mL

99.993%

 

99.997%

 

994710

Turbidity

 

0.5 NTU

29 NTU

0.12 NTU

0.09

NTU

99.59%

 

99.69%

 

994710

Lead: @pH 6.5

0.015

mg/L

0.16 mg/L***

0.001mg/L

0.001

mg/L

99.4%

 

99.4%

 

994708

Lead: @pH 8.5

0.015

mg/L

0.16 mg/L***

0.002 mg/L

0.001

mg/L

98.8%

 

99.4%

 

994709

It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised.

Model WF-NLC250 Change cartridge at least every 6-9 months. Use replacement cartridge NLC 250, part# 9902. 2002 suggested retail price of $39.95 U.S.A./S49.95 Canada. Prices are subject to change without notice.

Model WF-LC400The filter monitor system measures the amount of water that passes through the filter and alerts you to replace the filter. When 90% of the filter's rated life is used, the filter indicator light changes from green to yellow. When 100% of the filter's rated life is used, the filter indicator light changes from yellow to red, and it is recommended that you replace the filter. Use replacement cartridge LC400,

part# 9902. 2002 suggested retail price of $39.95 U.S.A./ $49.95 Canada. Prices are subject to change without notice.

Refer to the front cover or "Assistance or Service" section for the Manufacturer's name, address and telephone number.

Refer to the "Warranty" section for the Manufacturer's limited warranty.

Application Guidelines/Water Supply Parameters

Water

Supply

City

or Well

Water

Pressure

30 - 120 psi

(207 - 827 kPa)

Water

Temperature

33 ° - 100°F

(0.6 ° - 37.8 ° C)

The product is for cold water use only.

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

*Test requirement is at least 100,000 particles/ml of AC Fine Test Dust.

**Cyst performance is % reduction based on NSF Standard 53.

***Test requirement is 0.15 mg/L + 10%. These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.

® NSF is a registered trademark of NSF International.

23

Page 23
Image 23
Kenmore 10651532101, 2220695, 10652522100, 10651559104, 10651562103, 10651562104, 10651274200 manual Product Data, Epa, Mcl