RULES FOR SAFE mNSTALLATmON & OPERATION
Read these rubs and the instructions carefully. Faiiure to follow the rubs and instructions couid cause bodiiy injury and/or property damage.
Check your iocai buiiding codes and utiiity standards. The installation must compiy with their rubs. Ground the humidifier to prevent eiectrb shock.
Follow a reguiar service and maintenance schedub.
Aiways shut off ebctrbity and water to humidifier before servicing.
When the furnace Mower is used for air conditioning, the humidifier switch should be turned "OFR" Never oil any part of the humidifier.
The humidifier must not be installed in an area where freezing is possibb.
WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or injury.
CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices.
KENMORE 3000 PRODUCT FEATURES:
@Self contained 120V 18 gallon model
@Designed for homes up to 3000 sq. ft.
@Works with Heat Pumps
@Quick electric and water disconnect
@
@Substantial water savings - no drain required
@Automatic water feed
@Convenient ON/OFF switch
ACCESSORmES AND ATTACHMENTS
These accessories and attachments can be purchased at Sears or by contacting Sears Parts: 1_800_366_7278 or online at wwwosearsocorn.
•Reservoir Liner (Part No.
Remote Installation Kit (Sears Stock No. 9372)
•Replacement Media Pad (Sears Stock No.
No.
TOOLS AND MATERmALS NEEDED
Safety glasses
o Straight edge ruler Pencil or grease pencil
Hand drill or grounded electric drill Drill bits, 5/32", 1/8"
Tin snips or metal cutting saw
Screwdriver (fiat point and phillips, medium size) File
Level Hammer
Small adjustable wrench o Center punch
Electrical wiring supplies (120V) as needed and of the type required by iocai codes.
o Materials needed for an alternate installation, use remote mounting kit, Sears Stock No. 9372 (see
Typica/ Remote insta//ations, Page ,5).
CARTON CONTENTS
Central Humidifier 3000
Hardware Package
-Screw (7): Fastens Plenum Stiffener to the Supply Air Plenum
-Conduit Connectors (6): Connects wires together during wiring steps
-Brass Inserts (2): Regulates water flow
-Brass Compression Sleeve (1): Aids in connection of plastic tubing to the Quick Disconnect Socket
-Capped Fastener: Secures upper case to Plenum Stiffener
Saddle Valve Package
-Saddle Valve
-Brass Compression Sleeve
-Brass Compression Nut
-Brass Insert
-Rubber Gasket
-Screws (2)
-Nuts (2)
Humidistat (Humidity Control) Package
-Humidistat
-Gasket
-Mounting Screws (2)
-Operating Instructions
-Wiring Diagram
1/4" Plastic Tubing (10 ft.) Float
Float Arm
Quick Disconnect Socket o Plenum Stiffener
o Maintenance Label
Owner's Manual
DO-mToYOURSELF CHECK UST
If you feel the following operations are within your skills, you should have no difficulty installing this humidifier.
Cutting and drilling sheet metal.
Using hand tools: screwdriver, wrench, etc. Hooking up line voltage electrical connections.