Kenmore 153.326563 55 GAL, 326863 50 GAL Topreventdamagetothetankandheatingelement,thetank, water

Models: 153.326763 40 GAL 153.326463 40 GAL 153.326562 55 GAL 153.326462 40 GA! 326862 50 GAL 153.326362 30 GAL 153.326663 50 GAL 153.326762 40 GAL 153.326662 50 GAL 153.326363 30 GAL 153.326563 55 GAL 326863 50 GAL

1 32
Download 32 pages 63.48 Kb
Page 26
Image 26
Topreventdamagetothetankandheatingelement,thetank

Neverusethiswaterheaterunlessitiscompletelyfullofwater.

Topreventdamagetothetankandheatingelement,thetank

mustbefilledwithwaterThewatermustflowfromthehot.

waterfaucetbeforeturning"ON"power.

A.*Condensationmaybeseenonpipesinhumidweatheror

pipeconnectionsmaybeleaking.

B.Smallamountsof waterfromthetemperature-pressure reliefvalvemaybeduetothermalexpansionorhighwater pressureinyourarea.

C.*Thetemperature-pressurereliefvalvemaybeleakingat thetankfitting.

D.Theelementmaybeleakingatthetankfitting.

Readandunderstandinstruction manualandsafetymessages beforeinstalling,operatingor servicingthiswaterheater.

Failuretofollowinstructionsand safetymessagescouldresultin deathorseriousinjury.

Instructionmanualmustremain withwaterheater.

Readthismanualfirst.Thenbeforecheckingthewaterheater

makesuretheelectricsupplyhasbeenturned"OFF",andnever

turntheelectricsupply"on"beforethetankiscompletelyfullof

water.

Usethisguideto checka "Leaking"waterheaterMany. suspected"Leakers"arenotleakingtanksOftenthesourceof. thewatercanbefoundandcorrected.

Ifyouarenotthoroughlyfamiliarwithelectriccodes,thewater

heater,andsafetypractices,contactyourlocalSearsService

Centertocheckthewaterheater.

improper installation and use may result

in property damage,

-Fill tank with water before operation.

• Before removing any access panels or servicing the water heater, make sure the electrical

supply to the water heater is turned "OFF".

Failure to do this could result in death, serious bodily injury, or property damage.

Turn electrical power "OFF", remove access panel and insulation cap with handle. If leaking around element, follow

proper draining instructions and remove element. Reposition or replace gasket on element. Place element into opening and

tighten securely. Then follow "Filling the Water Heater"

instructions in the "Installation Instructions" section.

E. Water from drain valve may be due to the valve being opened slightly

F. *The drain valve may be leaking at the tank fitting.

G Water in the water heater bottom or on the floor may be from

condensation, loose connections or the temperature- pressure relief valve. DO NOT replace the water heater until a full inspection of all possible water sources is made and necessary corrective steps taken.

Leakage from other appliances, water lines, or ground seepage should also be checked.

Note: To check where threaded portion enters tank,

insert cotton swab between jacket opening and fitting. if cotton is wet, follow "Draining" instructions in the

"Service and Adjustment" section and then remove fitting. Put pipe dope or teflon tape on the threads and replace. Then follow "Filling the Water Heater" instructions in the "Installation Instructions'section.