LIFT OUT TABTO

LIFT OUT TABTO

 

 

 

UNCLIP TERMINAL

JACK_

_-,

COVER FROM

 

 

PLASTIC TABS ON

THERMOSTAT

TERMINAL

COVER

 

t BOTH SIDES OF

 

 

 

 

CLIPPED

TO _

TERMINAL COVER

 

THERMOSTAT AT

HOL IT IN PLACE

 

THIS POINT

 

 

 

_

tHERMOSTAT

 

 

 

BRACKET

_-TANK

_'_ " ELEMENT

THERMOSTAT

FIGURE 16.

5.Remove the screws from terminal 2 of the element, and move the looped end of the wire aside.

FIGURE 17.

6.The buss bar is labeled 5500 W. Place the buss bar over terminals 2 and 3 with the 5500 W visible. Install the extra screw provided into terminal 3.

FIGURE 18.

7.The wire removed from terminal 2 has a looped end. It must remain looped and now be placed (as shown) on top of the buss bar, over the opening of terminal 2, and secured using the remaining screw.

FIGURE 19.

8.Tightenterminals2 and3 to ensureproperelectrical connection.

Fire and E×plosion Hazard

Failure to tighten screws can cause a fire.

Failure to do this could result in death, serious bodily injury, or property damage.

Failure to tighten terminal screws can cause a fire which can result in DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.

9.Replace terminal cover on thermostat making sure that the locking tabs on the terminal cover are in place.

Fire and E×plosion Hazard

= Thermostat must be flush

againstthe tank.

Make sure terminal cover is in

place and the insulation

replaced.

e Failure to do this could result in death, serious bodily injury, or property damage.

Make sure the thermostat is flush against the tank, the terminal cover is in place, and the insulation is replaced. Failure to do

so can result in DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.

10.Replace the insulation cap with handle so that it completely covers the thermostat and element.

Q

FIGURE 20.

13