FAQs |
|
|
| ||
|
|
| |||
15. How do I temporarily | Any time your program is running and you would like to override it for a specific amount | ||||
Override the program and | of time, press | or | until the temperature you want is displayed. The display will | ||
Hold Til Timing? | indicate HOLD, and the number of hours remaining in the hold period will be indicated | ||||
|
| with the word HRS. To adjust the length of time for the override, press TIME FWD or | |||
|
| TIME BACK. The time you select will become the new number of hours for the Hold Til | |||
|
| timing. Once your time is selected, let the thermostat revert back to normal operation on its | |||
|
| own to accept the change. |
|
|
|
|
|
|
| ||
16. What is the | Many furnaces have safety devices that shut the system down when a | ||||
thermostat Click Test? | occurs in the furnace. If the thermostat is turned off or the call for heat is cancelled (by | ||||
|
| lowering and then raising the set temperature) the furnace may start operating again. A | |||
|
| diagnostic to see if the thermostat is operating when the room temperature is below the | |||
|
| thermostat setting (in heat) is to lower the setting below the room temp. Within about 3 | |||
|
| seconds the thermostat should make a soft click sound. This sound is the thermostat turning | |||
|
| off the call for heat and usually indicates the thermostat is operating properly. If the | |||
|
| thermostat does not click you would be suspicious of the thermostat and try resetting it by | |||
|
| following it’s reset operation. If the thermostat does not click after being reset contact your | |||
|
| heating and cooling service person or place of purchase for a replacement. If the thermostat | |||
|
| clicks and the heat works intermittently contact the furnace manufacturer or local service | |||
|
| person. They will want to observe the condition when it is not working. | |||
|
|
|
| 31 |
|
|
|
|
|
|
FAQs