Service Button Menu (Continued)
7 TIME FWD
SERV TIME | (ON) | Selects Routine Maintenance Service Call Reminder. |
(OFF) Days | or |
|
or | (OFF) |
|
REM SERV TIME |
|
|
No. of Days |
|
|
8 | TIME FWD | SET SERV TIME | 25 to 1975 | Selects time intervals in increments of 25 days. The RUN |
| (If SERV TIME is ON) | (175) Days |
| time is the calendar time from when it is entered or reset. |
|
|
|
|
PRGM
RUN
Return | s t o Norma | l Operati | on. |
Humidifier
Maintenance Indicator.
This feature allows the thermostat to
display the words CHCK PAD (check humidifier) after a set time of
humidifier operation. This is a reminder to maintain or clean your humidifier. The factory set interval for CHCK PAD to be displayed is 100 hours of humidifier operation. This
should be adjusted with respect to the humidifier’s recommended mainte- nance schedule.
Air Filter Change-Out Indicator.
This feature allows the thermostat to
display the words | CHNG FLTR |
(change filter) after a set time of fan | |
operation. This is a reminder to change |
or clean your air filter. The factory set interval for CHNG FLTR to be displayed is 200 hours of fan opera- tion. This can be set anywhere from 0
to 1975 hours in 25 hour increments. A selection of OFF will cancel this feature. When CHNG FLTR is
23
displayed, you can clear it by pressing |
| |||
the SERVICE |
| button. This resets |
| |
the timer and starts counting the hours |
| |||
until the next filter change. The |
|
| ||
following steps will allow you to |
|
| ||
change the number of hours for filter |
| |||
|
|
|
| |
1. If you see |
| CHNG FLTR on the | ||
display, press the | SERVICE | button | ||
once to reset the timer. If you do not |
| |||
see CHNG FLTR proceed to step 2. | ||||
When the | SERVICE | button is pressed |
twice, the display will show the The