Optimal Dehumidification Mode

Programmable Dehumidification

Optimal Dehumidification Mode

(OPTM DHUM)

(User Menu step 6)

When turned on

this feature automatically reduces

 

indoor humidity if humidity is 2%

 

above setting. Humidity is set by

 

pressing the

HUMIDITY

button

when in the appropriate mode, in this

 

case Cooling, and pressing the

 

or

buttons to set desired

 

humidity level followed by pressing

 

RUN

PROGRAM

 

. This dehumidifi-

cation feature may use more energy by making dehumidification a priority initiating a call for cooling if humidity is 2% above desired setting. This feature may also over-cool the condition space by up to 3 degrees to achieve the desired humidity level.

Fahrenheit or Celsius

Temperature Display.

(User menu, Step 7) This thermostat

is factory set to display temperature in Fahrenheit. If you prefer, you may configure the thermostat to display

Celsius. See the

 

CONFIGURATION
Section, page 4.

 

 

Single Period Fan Control.

(User menu, Step 8)

This feature

allows you to have the fan run for a

predetermined period of time by

pressing the

FAN

key twice within 1.5

seconds. If a time is set in the User menu (page 4, step 8) the display will

show FAN, # hrs and PRG FAN ON for six seconds. After six seconds the display will continue to indicate PRG FAN ON for the time period selected. After this time period, the fan will return to normal operation. To return the

fan to normal operation before the end of the time period, press the FAN button.

Beeper on.

(User menu, Step 9) The thermostat has a beeper that will emit a tone when any key is pressed. In the user menu, the BEEP feature can be turned OFF using

or

to provide silent key

operation.

 

Heat Fast.

(User menu, Step 10) This feature, when set to ON, will bring the second stage of heating on any time you manually raise the temperature three or more degrees above room temperature. If HEAT FAST is set to OFF, the thermostat will delay the second stage from 0 to 30 minutes based on how well the first stage is keeping up with your setting.