Cool Fast. |
|
| |
(User menu, Step 11) | This feature, | ||
when set to | ON | , will bring the second | |
stage of cooling on any time you |
| ||
manually lower the temperature three |
| ||
or more degrees below room tempera- |
| ||
ture. If | COOL FAST | is set to | OFF , |
the thermostat will delay the second |
| ||
stage from 0 to 30 minutes based on |
| ||
how well the first stage is keeping up |
| ||
with your setting. |
|
| |
Optional Remote Temperature | |||
Sense. |
|
| |
(User menu, Step 12,13,14,15) | Up to |
three remote sensors
you want to install the thermostat in a separate room to prevent tampering. After installing and connecting the remote sensor(s) to the thermostat, the installer can enable each remote indoor temperature sensor (A, B, and/or C). When operating with remote sensor(s), the thermostat will calculate an average of the sensed temperatures in all enabled sensor locations (A, B, C and/or L), then display the average temperature as the room temperature. The temperature at each remote sensor can be displayed by pressing the light button twice within one second. With the thermostat in program run or hold mode. Temperatures at the outdoor and indoor remote sensors will be displayed with subsequent presses of the light button in the following order (if connected): outdoor sensor, sensor L, A, B, C. You can also assign each sensor different priorities during
9
different program periods. This allows |
|
| ||
the system to maintain a comfortable |
|
| ||
environment by giving higher priority |
|
| ||
to occupied locations. At the same |
|
| ||
time, giving lower priority to unoccu- |
|
| ||
pied locations enhances efficient |
|
| ||
system operation. EXAMPLE: Your |
|
| ||
home has bedrooms on the upper level |
|
| ||
and a guest bedroom on the main |
|
| ||
level, along with the living room, |
|
| ||
kitchen, etc. The thermostat (sensor L) |
| |||
is located in the hall on the main level. |
| |||
Remote sensors are located on the |
|
| ||
upper level (sensor A) and the guest |
|
| ||
bedroom (sensor B). The lower level |
|
| ||
would be occupied in the | DAY |
| ||
and | EVE | periods. The upper level |
| |
would be occupied in the | NHT | and | ||
MOR | periods. With no guest in the |
| ||
guest | bedroom, the sensors could be |
|
|
programmed as follows:
Configuration