FAQs | ||
|
| |
(cont. ) | is dependent on system sizing, thermostat location, etc. Note: The thermostat display only | |
13.Why does the system run | displays whole numbers. Internally the thermostat calculates decimals. | |
with the setpoint and room | In heating as the room temperature increases the system will continue to run until the | |
temperature the same? | ||
thermostat reaches the high side of the temperature setpoint. | ||
| ||
|
| |
14. How do I reset my | There are 3 possibilities to consider, excluding tampering. | |
thermostat? | 1. Loss of power from the system, 24VAC should be constant to maintain a display. | |
| ||
| 2. Static electricity or a voltage spike from the heating equipment might be resetting the | |
| thermostat. Static electricity can be eliminated by touching something before touching the | |
| thermostat to dissipate the static charge. A voltage spike from the equipment can be | |
| eliminated using an isolation relay as described in the link below. | |
| ||
| You can also check the wire routing to verify the thermostat or remote wires are not running | |
| parallel to high voltage lines with high inductive loads which could (in extreme cases) | |
| create a voltage spike at the thermostat. | |
| 3. Thermostat not functioning properly. A simple test would be to bench test one of the units | |
| for a couple of days to see if it resets or move it to another system where a reset has never | |
| occurred. | |
|
|