Automatic Heat/Cool

Automatic Heat/Cool

 

 

Changeover

 

 

If you have a heating/cooling system,

 

the thermostat can be set to automati-

 

 

cally switch the system from heating to

 

cooling as needed. To set your

 

 

thermostat to this operating mode,

 

 

press the

 

SYSTEM button until

AUTO

is displayed on the screen. To change

 

 

the mode of operation from heating or

 

 

cooling can be accomplished by

 

 

pressing the

 

and

 

buttons

at the same time, this will change the

 

 

setpoint temperature displayed to the

 

 

setpoint of the other mode. This will

 

 

allow you to modify both the

 

HEAT
and COOL

 

setpoints to accommodate

 

a HOLD

condition while in Automatic

 

Changeover mode.

Note

: For proper

Automatic Changeover mode the

 

° F

heating setpoint must be at least 1

 

lower than the cooling setpoint in each program period. If the heating setpoint

is equal to or higher than the cooling setpoint this causes is conflict. The thermostat will indicate a conflict by flashing the setpoint and will resolve the conflict by choosing a heating setpoint that

is an average of the two program setpoints. The cooling setpoint will be two degrees higher than the heating setpoint.

Adjustable Temperature Display

The room temperature display can be adjusted to read higher or lower by following the configuration menu and adjusting the temperature to a higher or lower value. The thermostat is calibrated at the factory to display a very accurate room temperature, but due to various conditions and/or personal preference, you may wish to adjust the thermostat display higher or

lower (up to 5 ° F). For example, if the

19

thermostat displays a room tempera-

ture of 70 ° but you want it to display 73 ° , you can adjust it. To adjust, refer

to the

USER

CONFIGURATION

section (page 4, step 1).

Programmable Fan Control

This feature allows you to have your fan operate continuously through one or more programmed time periods.

This is useful if you want constant air circulation in your location during a specific time period. If you do not use this feature, the fan will cycle normally with the heating and cooling system.

Programmable Vacation Time/ Temperature Operation.

The VACATION mode allows you to program the thermostat to hold a constant temperature for 1 to 29 days. At the end of the day and time you

select, the thermostat will return to