White Rodgers F95-391 step, On L, Adjustable Humidity Display RH, User Menu The room, page

Models: F95-391

1 42
Download 42 pages 50.7 Kb
Page 9
Image 9
ON L

minutes (or 3 hours, 45 minutes if

EMR

ON L

is selected). The maximum time in

 

cooling and heat pump applications is 3 hours and 45 minutes. Cooling or heat pump applications start earlier because it takes longer to reach the desired temperature. This feature also minimizes the use of the auxiliary stages if conditions are such that the compressor stages are adequate to reach the desired setpoint.

To select or deselect this feature, refer to the CONFIGURATION section (page 4, step 2).

Adjustable Humidity Display (RH)

(User Menu step 3) The room

humidity display can be adjusted to read higher or lower by following the configuration menu and adjusting the humidity to a higher or lower value. The thermostat is calibrated at the factory to display a very accurate room humidity, but due to various

conditions and/or personal preference,

 

you may wish to adjust the thermostat

 

display higher or lower (up to +/-

 

20%). For example, if the thermostat

 

displays room humidity of 40% but

 

you want it to display 43% you can

 

adjust it. To adjust, refer to the

 

CONFIGURATION

section

(page 4,

step 3).

 

 

Programmable Automatic Humidity Reduction (DRY)

(User Menu step 4)

This feature automatically lowers humidity setting when the outside temperature drops. This is to prevent the interior windows/walls from reaching the dew point where water condenses on surfaces. To achieve automatic humidity reduction, the thermostat lowers the humidity when furnace cycles are long. When the furnace runs shorter cycles, it increases

7

humidity. For suggested settings see table below.

Programmable Dehumidification

Optimal Comfort Mode (OPTM

CMFT)

(User Menu step 5)

When turned on
this feature automatically reduces

 

indoor humidity during calls for

 

cooling if humidity is 2% above

 

setting. Humidity is set by pressing the

 

Humidity button when in the appropri-

 

ate mode, in this case Cooling, and

 

pressing the

or

buttons to

set desired humidity (range 40 to 95) level followed by pressing Run Program. This dehumidification

feature uses less energy by maintaining temperature and dehumidifying only when a call for Cooling is required.

Configuration