Kenmore 153.326662 50 GAL, 326863 50 GAL owner manual Maximum Fuse, Minimum, Model, Gals.Per, Lower

Models: 153.326763 40 GAL 153.326463 40 GAL 153.326562 55 GAL 153.326462 40 GA! 326862 50 GAL 153.326362 30 GAL 153.326663 50 GAL 153.326762 40 GAL 153.326662 50 GAL 153.326363 30 GAL 153.326563 55 GAL 326863 50 GAL

1 32
Download 32 pages 63.48 Kb
Page 5
Image 5
MAXIMUM FUSE

ThankYouforpurchasingSearswaterheaterProperly. installedandmaintained,it shouldgiveyouyearsoftrouble freeserviceItisstronglysuggestedthatthisnewwaterheater. beprofessionallyinstalled,contactthelocalSearsService CenteroranySearsstoreTheywillarrangeforprompt,quality. installationbySearsauthorizedcontractors.

Abbreviations Found In This Instruction Manual:

UL - Underwriters Laboratories Inc.

NEC - National Electrical Code

ANSI -American National Standards Institute

Read the "General Safety" section, page 3 of this manual first and then the entire manual carefully. If you don't follow the safety rules, the water heater will not operate properly. It could cause DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE.

This manual contains instructions for the installation,

operation, and maintenance of this electric water heater. It also contains warnings throughout the manual that you must read and be aware of. All warnings and all instructions are essential to the proper operation of the water heater and your safety. Since we cannot put everything on the first few

pages, READ THIS ENTIRE MANUAL BEFORE ATTEMPTING TO INSTALL OR OPERATE THE WATER HEATER.

The installation must conform with the instructions in this manual; electric company rules; and Local Codes, or in the

absence of Local Codes, with the current edition of the NEC - National Electrical Code, NFPA 70. This publication

is available from your local government or public library or

electric company or by writing Underwriters Laboratories

Inc., 333 Pfingsten Road, Northbrook, IL 60062.

If after reading this manual you have any questions or do

not understand any portion of the instructions, call Sears Service Center.

Carefully plan the place where you are going to put the water

heater. Correct electrical wiring and connections are very important in preventing death from possible electrical shock and fires.

Examine the location to ensure the water heater complies with the "Facts to Consider About the Location" section.

For California installation this water heater must be braced,

anchored, or strapped to avoid falling or moving during an

earthquake. See instructions for correct installation procedures.

Instructions may be obtained from the California Office of the

State Architect, 400 P Street, Sacramento, CA 95814.

Massachusetts Code requires this water heater to be installed

in accordance with Massachusetts 248-CMR 2.00; State

Plumbing Code and 248-CMR 5.00. In the Commonwealth of

Massachusetts, this product must be installed by a licensed plumber or gasfitter.

 

 

 

DIMENSIONS

 

 

 

ELEMENT

 

MAXIMUM FUSE

 

TANK

 

 

RECOVERY

RATE

WATTAGE

MINIMUM

OR CIRCUIT

 

IN INCHES (mm)

MODEL

CAPACITY

GALS.PER

HOUR

@240

VOLTS

WIRE SIZE*

BREAKER

 

 

 

 

NUMBER

IN GALLONS

DIA.

HEIGHT

,@_90°FRise

UPPER

LOWER

{GAUGE)

SIZE (AMPS)

 

 

 

 

 

 

153.326362

3O

I8.0

(457)

46.5

(I181)

17.3

 

3800

3800

12

2O

153.326363

25.0

 

3800

5500

10

3O

 

 

 

 

 

 

 

 

153.326462

4O

I8.0

(457)

59.5

(1511)

17.3

 

3800

3800

12

2O

153.326463

25.0

 

3800

5500

10

3O

 

 

 

 

 

 

 

 

153.326562

55

20.5

(521)

60.25

(I530)

17.3

 

3800

3800

12

2O

153.326563

25.0

 

3800

5500

10

3O

 

 

 

 

 

 

153.326662

50

23.0

(584)

49.0

(1245)

17.3

 

3800

3800

12

2O

153.326663

25.0

 

3800

5500

10

3O

 

 

 

 

 

 

153.326762

4O

20.5

(521)

44.0

(II18)

17.3

 

3800

3800

12

2O

153.326763

25.0

 

3800

5500

10

3O

 

 

 

 

 

 

 

 

153.326862

50

26.5

(673)

34.0

(864)

17.3

 

3800

3800

12

2O

153.326863

25.0

 

3800

5500

10

3O

 

 

 

 

 

 

 

 

*Wiring size based on standard 60°C copper wire. If distance from fuse box to water heater is more than 90 feet, refer to your local electrical code.