Program The Timer

SET PRESENT TIME OF DAY

If the words PRESENT TIME do not show in the display, press the SELECT button until they do show in the display. Press the UP or DOWN buttons to set the present time. Press UP to move the display ahead; press DOWN to move the time backward. If the present time is between noon and midnight, be sure PM shows. If the present time is between midnight and noon, be sure AM shows. Each press of the UP or DOWN buttons changes the time by one (1) minute. Holding the buttons in changes the time 32 minutes each second.

PM

PRESENT TIME

AM

PRESENT TIME

FIG. 26

SET WATER HARDNESS NUMBER

To set the water hardness number, complete the following steps:

1.Press the SELECT button once to display 25 (flashing) and HARDNESS. The grains per gallon (gpg) hardness of your water supply is on your water analysis report. Be sure to enter water test results on the Facts & Figure Chart on page 3.

2.If your water supply contains iron, compensate for it by adding to the water hardness number. For example, assume your water is 20 gpg hard and contains 2 ppm iron. Add 5 to the hardness number for each I ppm of iron. In this example, you would use 30 for your hardness num- ber.

2 ppm iron x 5 = 10

20 gpg hardness

+10

30 HARDNESS NUMBER

3.Press the UP or DOWN buttons to set your water hard- ness number in the display. The DOWN button moves the display to 1. The UP button moves the display to the high- est setting (see maximum setting for your model in the specifications).

NOTE: Each press of the UP or DOWN button changes the display by 1 between 1 and 25. Between 25 and the highest number, the display changes 5 at a time (25, 30, 35, etc.) Holding the UP or DOWN button in changes the display twice each second.

AM

HARDNESS

RECHARGE

TIME

FIG. 27

SET REGENERATION TIME

To complete setting the regeneration time, complete the fol- lowing steps:

1.Press the SELECT button to display 2:00 AM (flashing) and RECHARGE TIME.

2.At the 2:00 AM recharge time setting, the softener begins regeneration (see pages 26 - 28) at 2:00 AM. This is a good time in most households because water is not being used. If a different recharge time setting would be better for your household, complete the following step.

3.Press the UP or DOWN buttons to set the desired recharge starting hour. Be sure to observe the AM-PM as you did when setting the present time of day.

Note: Each press of the UP or DOWN buttons changes the display one hour. Holding the but- tons in changes the display twice each sec- ond.

4.Press the SELECT button once again, to com- plete initial programming, and the current time of day shows in the display.

Questions? Call The Kenmore Water Line 1-800-426-9345

18

Page 18
Image 18
Kenmore 350 Series, 625.393560 warranty SET Present Time of DAY, SET Water Hardness Number, SET Regeneration Time