I_

SECTION5 _ __

SERVICE TECH. INFORMATION

D. WATER FLOW THROUGH THE FILTER VALVE

SERVICE CYCLE

 

INLET

 

(UNFILTERED

WATER)

VALVE OUTLET

TOP

 

(FILTERED

 

DISTRIBUTOR

POSITION

WATER)

 

SWITCH

 

TANK

 

RESIN

 

 

_BED

s

 

4_ _ 4_,S #

RESIN

__

kX BOTTOM

 

DISTRIBUTOR

 

Unfiltered water enters the vane inlet port. Internal valve porting routes the water down and out

the top distributor, into the resin tank. Unfiltered water is filtered as it passes through the resin bed,

then enters the bottom distributor. Filtered water flows back into the valve and out the valve outlet, to the house water pipes.

FILL

CYCLE

VALVE CAM

POSITION

ROTOR & DISC

SWITCH

 

VENTURI

 

FILL FLOW

VALVE INLET

PLUG

FILL

(UNFILTERED WATER)

(FILTERED)

 

VALVE OUTLET • (FILTERED WATER)

To begin a regeneration, the electronic timer energizes the circuit to the valve motor. The valve motor rotates the rotor and disc and the valve cam until the position switch lever drops to open the motor circuit, when the valve reaches FILL position. As the rotor and disc rotates, the port

opens for filtered water to fill through the venturi. Fill flow continues to the brine valve, and into

the salt storage tank. Filtered water is still available to the house lines.

5-5

Problems, Questions? Call 1-800-426-9345 Kenmore Water Line

Page 23
Image 23
Kenmore 625.348261 owner manual Water Flow Through the Filter Valve, Service Cycle