OTHER THINGS TO KNOW

A.

DIMENSIONS

/ SPECIFICATIONS

 

 

 

 

 

Pretreatment

Needed

 

 

 

For Higher

Amounts

 

 

Supply Water

Limits

Listed

MAX, WATER HARDENSS:

10 gpg

Water Softener

 

 

 

Water

Softener and/or

MAX, CLEAR WATER IRON:

2 ppm

 

Iron Filter

MAX, CHLORINE*:

1 ppm

Activated Iron Filter

MAX, TANNIN:

3 ppm

 

 

 

MAX, pH:

8,0

 

 

 

MAX, NITRATES:

2 mg/L

 

 

 

MAX, SUSPENDED SOLDS*:

1,0 NTU

 

 

INLET WATER PRESSURE LIMITS:

.......................

20-125

psi

 

 

MAX, INLET WATER TEMPERATURE:

120°F

 

 

 

MIN, INLET WATER FLOW:

4 gat/min,

 

 

MIN, INLET AND OUTLET PIPE SIZE:

3/4 inch

 

 

BACKWASH FLOW RATE (at 35 psi

inlet pressure):

1 gal/min.

 

 

MIN, SALT USAGE AT EACH REGENERATION:

5 Ibs

 

 

 

MIN, FREQUENCY OF REGENERATIONS:

every 2 days

 

 

CAPACITY RATING:

See Rating Decal on Filter

 

 

* continuous

 

 

 

 

 

4-2