SECTION 5
SERVICE TECH. INFORMATION
5C. WATER FLOW THROUGH THE SOFTENER VALVE
FAST RINSE CYCLE
During ST RINSE the rotor & disc is positioned so water flow enters the resin tank through the top distributor and exits through the bottom distributor to the drain
The solid state timer again energizes the motor to return the valve to service s the valve rotates the position switch lever drops to open the circuit The valve remains positioned in service until the timer initiates the next regeneration
26