SECTION 4
OTHER THINGS TO KNOW
4A. DIMENSIONS/SPECIFICATIONS
FIG. 12
BYPASS VALVES
|
|
|
|
| INCHES |
| CM |
|
|
|
|
|
| ||
|
| A | Salt Tank Height |
| 102.2 | ||
|
| B | Resin Tank Diameter (nominal) | 9 |
| 22.7 | |
|
| C | Resin Tank Height (nominal) | 40 |
| 101.6 | |
|
| D |
| 105.4 | |||
|
| E | Overall Height | 46 |
| 116.8 | |
|
| F1 | Length |
|
| 49.5 | |
|
| F2 | Width |
|
| 41.9 | |
|
| — | Distance between |
| 8.6 | ||
|
|
| center lines |
|
|
|
|
MODEL NO. 625.3485400 AND 625.3485500 | TIMER AR CODE AR31 |
NOTE: Please see the rating decal for water softener operating capacity, salt usage and service flow rate/pressure loss performance specifications. Performance specifications are validated by the Water Quality Association (WQA). The rating decal is located on the rim, under the salt hole cover (see page 28).
WATER SUPPLY TO WATER SOFTENER
MINIMUM WATER SYSTEM FLOW (gpm) | 3 |
MAXIMUM WATER TEMPERATURE (°F) | 120 |
MAXIMUM WATER HARDNESS (gpg) | 110 |
MAXMUM “CLEAR WATER”IRON (ppm) | 8 |
SALT FOR WATER SOFTENER
TYPE OF SALT NEEDED | Nugget/Pellet |
ALTERNATE TYPE OF SALT | Pure, evaporated, compacted |
| water softener salt |
STORAGE CAPACITY (pounds) | 200 |
OTHERS
TYPE OF ION EXCHANGE MATERIAL (resin) | High Capacity | |
AMOUNT OF RESIN (cu.ft.) |
| 1.0 |
REGENERATION (RECHARGE) CYCLE TIME (min.) | ||
FILL |
| |
BRINING/BRINE RINSE |
| |
BACKWASH |
| 7 |
FAST RINSE |
| 3 |
TOTAL REGENERATION TIME | ||
gpm = gallons per minute | psi = pounds per square inch | |
gpg = grains per gallon | ppm = parts per million |