Kenmore 625.3485500 5C .. WATER FLOW THROUGH THE SOFTENER VALVE, Section, Service Cycle

Models: 625.3485500 625.3485400

1 32
Download 32 pages 44.45 Kb
Page 25
Image 25
5C .. WATER FLOW THROUGH THE SOFTENER VALVE

SECTION 5

SERVICE TECH INFORMATION

5C .. WATER FLOW THROUGH THE SOFTENER VALVE

SERVICE CYCLE

Hard water enters the valve inlet port. Internal valve porting routes the water down and out the top distributor, into the resin tank. Hard water is softened as it passes through the resin bed, then enters the bottom distributor. Soft water flows back into the valve and out the valve outlet, to the house soft water pipes.

FILL CYCLE

To begin a regeneration, the electroic timer energizes the circuit to the valve motor. The valve motor rotates the rotor and disc and the valve cam until the position switch lever drops, to open the motor circuit and position the valve in FILL. As the rotor and disc rotates, the port opens for SOFT water fill through the venturi. Fill flow continues to the brine valve, and into the salt storage tank. Soft water is still available to the house lines.

25

Page 25
Image 25
Kenmore 625.3485500 5C .. WATER FLOW THROUGH THE SOFTENER VALVE, Section, Service Tech Information, Service Cycle