Pressure Drop (PSI) vs. Flow Rate (GPM)
40
35
30
25
g
20
.= |
| 350 | Series |
| 15 | 8.0gpm | @ 14psi |
t_ |
|
| |
|
|
|
I
lO
5
0 | I |
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Flow Rate (GPM)
FIG. 50
Intermittent flow rate does not represent the maximum service flow rate used for determining the soften- ers rated capacity and efficiency. Continuous operation at flow rates greater than the service flow rate may affect capacity and efficiency performance.
OTHER | SPECIFICATIONS |
|
| MODEL | 38356 | MODEL | 39356 | ||||
Type of | ion exchange | material (resin) | high capacity | high capacity | |||||||
Amount | of resin | (cu. ft.) |
|
| 0.92 | 0.92 | |||||
Rated Softening | Capacity | (Grains | @ Pounds Salt Dose) | 14,200 | @ 2.8 | 14,200 | @ 2.8 | ||||
|
|
|
|
|
|
|
| 29,900 | @ 8.8 | 29,900 | @ 8.8 |
|
|
|
|
|
|
|
| 35,600 | @ 14.7 | 35,600 | @ 14.7 |
Efficiency | Rating | (Grains | / Pound | of Salt @ Minimum Salt Dose) | 5060 | @ 2.8 | 5060 @ 2.8 | ||||
Rated Service | Flow | Rate (gpm) |
| 8.0 | 8.0 | ||||||
Pressure | Drop | at Rated Service Flow Rate (psi) | 14 | 14 | |||||||
Intermittent | Flow | Rate @ | 15 psi (gpm) | 8.5 | 8.5 | ||||||
Max. Drain Flow Rate (gpm) |
| 2.0 | 2.0 |
These systems conform to NSF / ANSI 44 for the specific performance claims as verified and substantiat- ed by test data.
The efficiency rating is only valid at the minimum stated salt dosage. These softeners were efficiency rated according to NSF /ANSI Standard 44.
Questions? Call The Kenmore Water Line
34