if Electronic Laundry

Center does not start:

u Is plug disconnected from power supply or is plug loose in outlet, not making good connection?

Is house fuse blown or circuit breaker off?

o Is lid closed during spin cycle? = Is dryer door closed?

o Have you touched START pad? o The internal motor protector will

stop motor if it is overheated, but

will automatically reset after motor cools.

if display window does not indicate desired setting:

=Have correct Cycle, Options, and Cycle Adjustments been selected?

o Has cycle setting accidentally been reprogrammed?

See "Personalized Cycle" in Oper-

ating Instructions to return to factory-set program or change per- sonalized cycle.

If water does not enter:

Are water valves turned on?

Are filter screens clogged? They are located at water valve ends of hoses.

If there is no hot water:

o Are hot and cold water hoses reversed? Hot water hose is iden- tified.

If water does not drain:

o Are there kinks in drain hose?

o Is drain system clogged or restricted?

*Is drain hose lower than 33" in

standpipe? This can cause siphon- ing and washer will continue to fill. See Installation Instructions for further information.

If water is leaking at

hose connection:

o Disconnect hose from valve. Remove rubber washer at end of

hose and replace with new washer. Reconnect hose to valve.

DO NOT overtighten.

[AW/lffiNINGJ Disconnect electri- cal supply cord before servicing Electronic Laundry Center° Failure to disconnect can cause electrical shock or serious personal injury°

if articles am still wet at end of spin cycle:

° Is load unbalanced? Unit is

designed to complete cycle with

unbalanced load which could leave articles damp. Redistribute articles and touch SPIN ONLY.

o Is drain system clogged or re- stricted?

If articles are not drying satisfactorily:

o Is tint screen clean?

Are exhaust duct and vent hood

free of obstruction or lint blockage?

o Is dryer operating on AIR ONLY cycle which provides no heat?

o Are there too many articles in dryer? Check loading section of this bookleL

o Is metal flexible duct kinked or pinched?

[AWARNING] Do not use plastic

flexible duct to exhaust dryer. Replace plastic duct with rigid or flexible metal duct.

Excessive lint can build up inside duct work creating a fire hazard and restricting air flow. Restricted air flow will increase drying time.

Convenience Light

(Models 91901 and 91951)

Replace convenience light with

fluorescent lamp number

F18T81CW/K24 by following these steps:

. Disconnect power cord from out-

]eto

* Remove the two access panel screws. Gently pulI panel down°

o Remove the two screws holding lens in place.

o Remove the two screws holding lamp clamps o

°Pull bulb away from socket with gentle pressure.

o Install new bulb by gently pushing terminals into sockets,

o Replace clamps, lens, and access panel securely with screws.

o Connect power cord to outlet°

Drum Light

(Models 91901 and 91951)

Replace drum light with incandes- cent bulb number 10C7 by following these steps:

o Disconnect power cord from out- let.

o Remove lamp cover by turning it counter-clockwiseo

€, Remove bulb by turning it a quarter turn to the left and gently pulling bulb from receptacle.

*Install new bulb and replace lamp cover.

= Connect power cord to outlet.

Optional

ories for your

Kenmore

Electronic Laundry Center

available from your nearest Sears Service Center.

Drying Rack PIN 145283-000

Syphon Break PIN 076660-000

Drain Hose, 9 Fto Long PIN !42337-000

,, For additional accessories check Laundry Center Parts List or your local Sears Service Center.