ntroduction
Thank You for purchasing a Seats water heater. Properly installed and maintained, it should give you years of trouble free service° If you should decide that you want the new water heater professionally installed, contact the local Sears Service Center or any Sears store. They wilt arrange for prompt, quality installation by Sears authorized contractors.
Abbreviations Found In This Instruction Manual
National Electrical
writing to UL.above.
Product | Specifications |
|
|
|
|
|
|
| |||
|
|
|
|
|
| ELEMHWF |
|
| MAXIMUM FUSE | ||
| TANK |
|
| RECOVERYRATE |
| WATTAGE | MINIMUM |
| OR CIRCUIT | ||
MODEL | CAPACITY | DIMENSIONS ININCHES | GALS. PER HOUR |
| AT 240 VOLTS | WIRE SIZE* |
| BREAKER | |||
NUMBER | IN GALLONS | DIAMETER | HEIGHT | @90°E RISE |
| UPPER |
| LOWER | (GAUGE) |
| SIZE (AMI'S) |
153,327165 | 30 | 23" | 30¼" | 17.3 |
| - |
| 3800 | 12 |
| 20 |
153,327166 | 25,0 |
| - |
| 5500 | I0 |
| 30 | |||
|
|
|
|
|
| ||||||
153,327265 | 40 | 25 ° | 32¼" | 17,3 |
| - |
| 3800 | I2 |
| 20 |
153.327266 | 25.0 |
| - |
| 5500 | 10 |
| 30 | |||
|
|
|
|
|
| ||||||
t53,327365 | 30 | I9" | 46¼" | t7.3 |
| 3800 |
| 3800 | : 12 |
| 20 |
153,327366 | 25.0 |
| 3800 |
| 5500 | t0 |
| 30 | |||
|
|
|
|
|
| ||||||
t53.327465 | 40 | 19" | 60" | !7.3 | . | 3800 | . | 3800 , | 12 | . | 20 |
153.327466 | 25.0 |
| 3800 |
| 5500 | 10 |
| 30 | |||
|
|
|
|
|
| ||||||
153.327565 | 50 |
|
| !7.3 |
| 3800 |
| 3800 | 12 |
| 20 |
153.327566 |
|
| 25.0 |
| 3800 |
| 5500 | t0 |
| 30 | |
|
|
|
|
|
| ||||||
153',327665 | 66 | 21" | 58_" | 17.3 | . | 3800 | . | 3800 . | 12 | . | 20 |
I53,,327666 | 23" | 60_" | 25.0 |
| 3800 |
| 5500 | 10 |
| 30 | |
|
|
|
|
|
| ||||||
153327865 | 80 |
|
| 17.3 |
| 3800 |
| 3800 | 12 |
| 20 |
153327866 | 25" | 59_" | 25.0 |
| 3800 |
| 5500 | t0 |
| 30 | |
|
|
|
|
*Wiring size based on standard 60°C copper wire. If distance from fuse box m water heater is more than 90 feet, refer to your local electri- ca! code.
.ring for the New
Read the "Safety Precautions" section, page 2 of this manual first and then the entire manual carefully If you don't follow
the safety rules, the water heater will not operate properly. It
could cause DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE.
This manual contains instructions for the installation, opera- tion, and maintenance of this electric water heater. It also
contains warnings throughout the manual that you must read and be aware of. All warnings and all instructions are essential
to the proper operation of the water heater and your safety. Since we cannot put everything on the first few pages, READ THIS ENTIRE MANUAL BEFORE ATFEMPTtNG TO INSTALL OR OPERATE THE WATER HEATER
The installation must conform with the instructions in this
manual; electric company rules; and Local Codes, or in the absence of Local Codes, with the current edition of the
National Electrical Code, This publication is available from your local government or public library or electric company or by writing Underwriters Laboratories, 333 Pfingsten Road, Northbrook, IL 60062.
installation
•If after reading this manual you have any questions or do not understand any portion of the instructions, call Sears Service Center.
"Carefully plan the place where you are going to put the water heater. Correct electrical wiring and connections are very
important in preventing death from possible electrical shock and fires,
Examine the location to ensure the water heater complies with the "Facts to Consider About the Locatioff' section,
For California installation this water heater must be braced, anchored, or strapped to avoid falling or moving during an earthquake. See instructions for correct installation proce- dures. Instructions may be obtained from the California office of the State Architect, 400 P Street, Sacramento, CA 95814