Kenmore 153.327666 Troubleshootin Guide, Operational Conditions, High Temperature Shut Off Systeh

Models: 153327465 40 GAL 153.327865 327266_J 40 GAI SHORT 153 327566 50 GAE 153327265 40 GA! SHORT 153.327366 153.327565 50 GAL 153.327866 80 GAL 153.327666 153O327165_' 30 GAT 153.327466 40 GAL SHORT 153.327365 153327166 30 GAI SHORT 153.327665

1 32
Download 32 pages 23.87 Kb
Page 22
Image 22
Troubleshootin Guide

Troubleshootin Guide

Operational Conditions

SMELLY WATER

In each water heater there is installed at least one anode rod (see

parts section) for corrosion protection of the tank. Certain water conditions wil! cause a reaction between this rod and the water.

The most common complaint associated with the anode rod is

one of a "rotten egg smell", This odor is derived from hydrogen sulfide gas dissolved in the water. The smell is the result of tour factors which must all be present for the odor to develop:

aa concentration ofsulfate in the supply water. h little or no dissolved oxygen in the water.

c. a sulfate reducing bacteria within the water heater. (This harmless bacteria is non-toxic to humans.)

d an excess of active hydrogen in the tank. This is caused by the corrosion protective action of the anode_

Smelly water may he eliminated or reduced in some water heater models by replacing the anode(s) with one of less active material,

and then chlorinating the water heater tank and all hot water lines. Contact the local Sears Service Center for further informa-

tion concerning an Anode Replacement Kit #9001453 and this Chlorination Treatment

If the smelly water persists after the anode replacement and chlo- rination treatment, we can only suggest that continuous chlori- nation and filtering conditioning equipment be considered to

RUMBLING NOISE

In some water areas, scale or mineral deposits will build up on

your heating elements. This buildup will ,,cause a rumbling noise

Follow Element Cleaning/Replacement' instructions to clean and replace the elements

HIGH TEMPERATURE SHUT OFF SYSTEH

The water heater has a high limit shut off system with a reset button located on the thermostat°

Follow the resetting instructions which refer to the high limit behind the access panel,

NOTE: If your water heater is connected m an "OFF PEAK"

clock, and uses the "3 wire lead" wiring diagram in the

'w_g;"tringDiagram" section, then the water heater will have a hi=limit on both the upper and lower thermostats. Follow the instructions to reset the hidimit behind the upper and lower access panels.

Before beginning, turn "OFF" electric'd power supply to the water heater.

¢

eliminate the water problena_

I

Do not remove the anode leaving the tank unprotected° By doing so, all warranty on the water heater tank is voided.

"AIR" IN HOT WATER FAUCETS

AWARNING

HYDROGEN GAS: Hydrogen gas can be produced in a hot water system that has not been used for a long peri- od of time (generally two weeks or more). Hydrogen gas is extremely flammable and explosive. To prevent the possibility of injury under these conditions, we recom- mend the hot water faucet be opened for several min- utes at the Idtchen sink before any electrical appliances which are connected to the hot water system are used (such as a dishwasher or washing machine). If hydrogen gas is present, there will probably be an unusual sound similar to air escaping through the pipe as the hot water faucet is opened. There must be no smoking or open flame near the faucet at the time it is open.

AWARNING

HAZARD OF ELECTRICAL SHOCKI Before removing any access panels or servicing the water heater, make sure the electrical supply to the water heater is turned "OFF". Failure to do this could result in DEATH, SERI-

OUS BODILY INJURY,OR PROPERTY DAHAGE.