Kenmore 327266_J 40 GAI SHORT, 153O327165_' 30 GAT Safety Precautions, Awarning, Iawarning

Models: 153327465 40 GAL 153.327865 327266_J 40 GAI SHORT 153 327566 50 GAE 153327265 40 GA! SHORT 153.327366 153.327565 50 GAL 153.327866 80 GAL 153.327666 153O327165_' 30 GAT 153.327466 40 GAL SHORT 153.327365 153327166 30 GAI SHORT 153.327665

1 32
Download 32 pages 23.87 Kb
Page 2
Image 2
Safety Precautions

Safety Precautions

_WARNING]

Improper installation, adjustment, alteration, service or maintenance can cause DEATH, SERIOUS BODILY INJURY,,OR PROPERTY DAMAGE. Refer to this manual for assis-_ tance or consult your local Sears Service Center for further_

Linformat on,

AWARNING

At the time of manufacture this water heater was provided with

a combination temperature-pressures relief valve certified by a nationally recognized testing laboratory that maintains periodic

inspection of production of listed equipment or materials, as meeting the requirements for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems, and the current edition of ANSI Z21.22 and the code requirements of ASME. If replaced, the valve must meet the requirements of local codes, but not lessthan a combination temperature and pressurerelief valve certified as meeting the requirements for Relief Valvesand Automatic Gas Shutoff Devices for Hot Water Supply Systems, ANSI Z2L22 by a nationally recognized testing laboratory that

maintains periodic inspection of production of listed equipment or materials.

The valve must be mad_ed with a maximum set pressure not to exceed the marked hydrostatic working pressure of the water heater (150 Ibsop.s.L) and a discharge capacity not less than the water heater input rate as shown on the model rat- ing plate. (Electric heaters - watts divided by 1000 x 3412 equal BTUtHr. rate.)

Your local jurisdictional authority, while mandating the use of a temperature-pressure relief valve complying with ANSI Z21.22 and ASME, may require a valve model different from the one fur- nished with the water heater

Compliance with such local requirements must be satisfiedby the installer or end user of the water heater with a locally pre-

scribed temperature-pressure relief valve installed in the desig- nated opening in the water heater in place of the factory fur- nished valve.

For safe operation of the water heater, the relief valve must not be removed from it'sdesignatedopening or plugged.

The temperature-pressure relief valve must be installed directly into the fitting of the water heater designated for the reliefvalveo Position the valve downward and provide tubing so that any dis-

charge will exit only within 6 inches above, or at any distance below the structural floor. Be certain that no contact is made

with any I;veelectrical part. The dischargeopening must not be blocked or reduced in size under any circumstances. Excessive length, over 30 feet, or use of more than four elbows can cause restriction andreduce the dischargecapacity of the valve.

No valve or other obstruction is to be placed between the relief valve and the tank. Do not connect tubing directly to discharge drain unlessa 6" air gap isprovided. To prevent bodily injury, haz- ard to life, or property damage, the relief valve must be allowed to dischargewater in quantiEesshouldcircumstances demand. If the discharge pipe is not connected to a drain or other suitable means, the water flow m_y cause property damage.

The Discharge Pipe:

Must not be smaller in size than the outlet pipe size of the valve, or have any reducing couplings or other res_ctionso

Must not be plugged or blocked.

Must be of material listed for hot water distribution_

Must be installed so as to allow complete drainage of both

the temperature.pressure relief valve, and the discharge pipe.

Must terminate at an adequate draln_

Must not have any valve between the relief valve and tank.

IAWARNING

HAZARD OF ELECTRICAL SHOCK! Before removing any access panels or servicing the water heater_ make sure the electrical supply to the water heater is turned "OFF"° Failure to do this could result in DEATH, SERIOUS BODILY INJURY,

I OR PROPERTY DAMAGE.

AWARNING

HOTTER WATER CAN SCALD" Water heaters are intended to produce hot water. Water heated to a temperature which will satisfy space heating, clothes washing, dish washing_ and other sanitizing needs can scald and permanently injure you upon contact. Some people are more likely to be permanently injured by hot water than others. These include the elderly, children, the infirm, or physically/mentally handicapped, tf anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a cer= lain temperature water at the hot water tap, then you must take special precautions, In addition to using the lowest possi- ble temperature setting that satisfies your hot water needs, a means such as a mixing valve, shall be used at the hot water taps used by these peopte or at the water heater_ Mixing valves are available at plumbing supply or hardware stores,

Follow manufacturers instructions for installation of the valves, Before changing the factory setting on the thermostat, read the "Temperature Regulation" section in this manual.

_WARNING

WATER HEATERS EQUIPPED FOR ONE VOLTAGE ONKY: This water heater is equipped for one type voltage only. Check the rating plate near the bottom access panel for the correct voltage. DO NOT use this water heater with any volt- age other than the one shown on the model rating plate. Failure to use the correct voltage can cause problems which

can result in DEATH, SERIOUS BODILY INJURY, OR PROP-

ERTY DAMAGE. If you have any questions or doubts consult your electric company.

AWARNING

INSULATING JACKETS; When installing an external water heater insulation jacket on an electric water heater:

a_DO NOT cover the temperature-pressure relief valve. b0DO NOT put insulation over the access covers or any

access areas.

c. DO NOT cover or remove operating instructions, and safe- ty related warning labels and materials affixed to the water heater.

AWARNING

Do not use this appliance if any part of it has been under water_ An electrical short or malfunction could occur. The

water heater should be replaced_

_ CAUTION

WATER HEATERS EVENTUALLY LEAK: Installation of the water heater must be accomplished in such a manner that if the tank or any connections should leak, the flow of water will not cause damage to the structure° For this reason, it is

not advisable to install the water heater in an attic or upper floor. When such locations cannot be avoided, a suitable

drain pan should he installed under the water heater. Drain pans are available at your local Sears Store. Such a drain pan must be piped to an adequate drain° Under no circumstances is the manufacturer or Sears to be held liable for any water damage in connection with this water heater°

Page 2
Image 2
Kenmore 327266_J 40 GAI SHORT, 153O327165_' 30 GAT, 153327265 40 GA! SHORT Safety Precautions, Awarning, Iawarning