Kenmore 153.327665, SHORT, 153O327165_' 30 GAT, 153327465 40 GAL Installation Instructions contd

Models: 153327465 40 GAL 153.327865 327266_J 40 GAI SHORT 153 327566 50 GAE 153327265 40 GA! SHORT 153.327366 153.327565 50 GAL 153.327866 80 GAL 153.327666 153O327165_' 30 GAT 153.327466 40 GAL SHORT 153.327365 153327166 30 GAI SHORT 153.327665

1 32
Download 32 pages 23.87 Kb
Page 11
Image 11
Installation Instructions (cont'd)

Installation Instructions (cont'd)

2.The convertible element is located behind the lower access

panel of the water heater, Remove the two screws securing the access panel, and remove panel,

3, Remove the insulation block to expose the opening,_

5, Remove the screws from terminal 2 of the element, and move the looped end of the wire aside.

6, The buss bar is labeled 5500 W. Place the buss bar over termi- nals 2 and 3 with the 5500 W visible. Install the extra screw

provided into terminal 3,

S5OOW

4o Lower Element: Lift out the tab as shown to unclip the terminal cover from the thermostat, The terminal cover can now be removed from the thermostat

7, The wire removed from terminal 2 has a looped end, It must remain looped and now be placed (as shown) on top of the buss bar, over the opening of terminal 2, and secured using the remaining screw°

TERMINAL

COVER

pLASTIC

TABS ON

CUPPED

TO THER-

/BOTH

SIDF_

OF

H OSTAT

AT THIS

TERMINAL

 

COVER

POINT

 

HOLD

IT

tN

 

 

 

PLACE_

 

 

 

8.Tighten terminals 2 and 3 to ensure proper electrical connection,

LOWER THERHO_TAT

JACKET

11

Page 11
Image 11