Installation Instructions (cont'd)
2.The convertible element is located behind the lower access
panel of the water heater, Remove the two screws securing the access panel, and remove panel,
3, Remove the insulation block to expose the opening,_
5, Remove the screws from terminal 2 of the element, and move the looped end of the wire aside.
6, The buss bar is labeled 5500 W. Place the buss bar over termi- nals 2 and 3 with the 5500 W visible. Install the extra screw
provided into terminal 3,
S5OOW
4o Lower Element: Lift out the tab as shown to unclip the terminal cover from the thermostat, The terminal cover can now be removed from the thermostat
7, The wire removed from terminal 2 has a looped end, It must remain looped and now be placed (as shown) on top of the buss bar, over the opening of terminal 2, and secured using the remaining screw°
TERMINAL | COVER | pLASTIC | TABS ON | ||
CUPPED | TO THER- | /BOTH | SIDF_ | OF | |
H OSTAT | AT THIS | TERMINAL |
| COVER | |
POINT |
| HOLD | IT | tN |
|
|
| PLACE_ |
|
|
|
8.Tighten terminals 2 and 3 to ensure proper electrical connection,
LOWER THERHO_TAT
JACKET