PERFORMANCE DATA SHEET

Base Grille Water Filtration System

Model TIKB1/TIRFKB1 Capacity 100 Gallons (379 Liters)

System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of

Chlorine Taste and Odor, Particulate Class I*; and against NSF/ANSl Standard 53 for the reduction of

Lead, Mercury, Atrazine, Benzene, Toxaphene, O-Dichlorobenzene, Cysts, Turbidity, Asbestos, Lindane,

Tetrachloroethylene, Endrin, Alachlor, Chlorobenzene, Ethylbenzene, ]q-HM, MTBE and VOC.

This system has been tested according to NSF/ANSl Standards 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSl Standards 42 and 53.

Substance

Reduction

NSF Reduction

Average

Influent

Challenge

Maximum

Average

Minimum

%

Average

%

Aesthetic

Effects

Requirements

Influent

 

Concentration

Effluent

Effluent

Reduction

 

Reduction

Chlorine Taste/Odor

50%

reduction

2.0

mg/L

2.0 mg/L

_+10%

0.08

mg/L **

2.0

mg/L

95.93

 

97.36

 

Particulate

Class I*

85%

reduction

3533333#/mL

At east 10,000 part c es/mL

22000

#/mL

11567

#/mL

99.38

 

99.67

 

Contaminant

 

NSF Reduction

Average

Influent

Challenge

Maximum

Average

Minimum

%

Average

%

Reduction

 

Requirements

Influent

 

Concentration

Effluent

Effluent

Reduction

 

Reduction

Lead: @ pH 6.5

0.010

mg/L

150 ug/L

0.15

mg/L

_+10%

1.0

ug/L

1 ug/L

 

99.33

 

99.33

 

Lead: @ pH

8.5

0.010

mg/L

157 ug/L

0.15

mg/L

_+10%

2.0

ug/L

1.08

ugiL

98.72

 

99.31

 

Mercury:

@ pH 6.5

0.002

mg/L

0.0058

mg/L

0.006

mg/L

_+10%

0.0002

mg/L

0.0002

mg/L

96.53

 

96.53

 

Mercury:

@ pH 8.5

0.002

mg/L

0.0057

mg/L

0.006

mg/L

_+10%

0.0002

mg/L

0.0002

mg/L

96.5

 

96.5

 

Benzene

 

 

0.005

mg/L

15 ug/L

 

0.015

mg/L

_+10%

0.5

ug/L

0.5

ug/L

96.67

 

96.67

 

O-Dichlorobenzene

0.6 mg/L

1750 ug/L

1.8 _+10%

 

1.0

ug/L

1.0

ug/L

99.94

 

99.94

 

Toxaphene

 

0.003

mg/L

15 ug/L

 

0.015

_+10%

1.0

ug/L

1.0 ug/L

93.33

 

93.33

 

Atrazine

 

 

0.003

mg/L

10 ug/L

 

0.009

mg/L

_+10%

2 ug/L

 

2 ug/L

 

80.8

 

80.8

 

Asbestos

 

 

99%

 

101 MFL

107to

108fibers/L tt

0.17

MFL

0.17

MFL

99.83

 

99.83

 

Live Cysts _

 

>99.95%

120,000/L

50,000/L

min.

8/12

 

 

1/L _

 

99.99

 

>99.99

 

Turbidity

 

 

0.5 NTU

11.4 NTU

11 _+1 NTU

0.41

NTU

0.24

NTU

96.4

 

97.89

 

Alachlor

 

 

0.002

mg/L

41.3

ug/L

0.04

_+10%

0.2

ug/L

0.2 ug/L

99.52

 

99.52

 

Endrin

 

 

0.002

mg/L

5.9

ug/L

0.006

_+10%

0.5

ug/L

0.3

ug/L

91.5

 

95.47

 

Ethylbenzene

 

0.7 mg/L

1867 ug/L

2.1 _+10%

 

0.70

ug/L

0.0588

ug/L

99.96

 

100

 

Lindane

 

 

0.002

mg/L

1.9

ug/L

0.002

_+10%

0.02

ug/L

0.02

ug/L

98.93

 

98.93

 

Chlorobenzene

0.6 mg/L

2.0

ug/L

2.0 _+10%

 

0.0005

ug/L

0.0005

ug/L

99.98

 

99.98

 

Tetrachloroethylene

0.005

mg/L

14.2 ug/L

0.015

_+10%

0.5

ug/L

0.5

ug/L

96.47

 

96.47

 

TTHM

 

 

0.080

mg/L

465

ug/L

0.45

_+20%

1.0

ug/L

0.5

ug/L

99.78

 

99.88

 

MTBE

 

 

0.005

mg/L

14 ug/L

 

0.015

_+20%

0.70

ug/L

0.52

ug/L

94.94

 

96.27

 

VOC

 

 

0.015

mgiL

0.3520

mg/L

0.300

_+10%

0.0060

mg/L

0.0008

mg/L

98.4

 

99.78

 

Test Parameters: pH = 7.5 + 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to 22°C).

It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised.

Model T1KBI: The filter monitor system measures the amount of

water that passes through the filter and alerts you to replace the filter.

Style 1 - When the filter indicator reads 10%, order a new filter. When the filter indicator reads 0%, it is recommended that you replace the filter.

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.

Refer to the front cover or "Accessories" section for the Manufacturer's name, address and telephone number.

Refer to the "Warranty" section for the Manufacturer's limited warranty.

Style 2 - When the filter indicator light changes from green to yellow, order a new filter. When the filter indicator light changes from yellow to red, it is recommended that you replace the filter. Use replacement cartridge T1RFKB1, part #9030. In Canada, use replacement cartridge T1RFKB1, part #9030B. 2007 suggested retail price of $41.99 U.S.A./S51.99 Canada. Prices are subject to change without notice.

These contaminants are not necessarily in your water supply. While testing was performed under standard laboratory conditions, actual performance may vary.

 

Application

Guidelines/Water

Supply

Parameters

Water

Supply

City

or Well

 

 

Water

Pressure

30 - 120 psi (207 -

827 kPa)

Water

Temperature

33 ° - 100°F

(0.6 ° -

37.8°C)

Service

Flow Rate

0.5

gpm (1.9

L!rain)

@ 60 psi

The product is for cold water use only.

*Class I particle size: >0.5 to <1 um

**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust. ttFibers greater than 10 um in length

_Based on the use of Cryptosporidium parvum oocysts

® NSF is a registered trademark of NSF International.

24

Page 24
Image 24
Kenmore WI0151336A manual Performance Data Sheet, Model TIKB1/TIRFKB1 Capacity 100 Gallons 379 Liters