PERFORMANCE DATA SHEET
Base Grille Water Filtration System
Model TIKB1/TIRFKB1 Capacity 100 Gallons (379 Liters)
System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of
Chlorine Taste and Odor, Particulate Class I*; and against NSF/ANSl Standard 53 for the reduction of
Lead, Mercury, Atrazine, Benzene, Toxaphene,
Tetrachloroethylene, Endrin, Alachlor, Chlorobenzene, Ethylbenzene,
This system has been tested according to NSF/ANSl Standards 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSl Standards 42 and 53.
Substance | Reduction | NSF Reduction | Average | Influent | Challenge | Maximum | Average | Minimum | % | Average | % | |||||||||||
Aesthetic | Effects | Requirements | Influent |
| Concentration | Effluent | Effluent | Reduction |
| Reduction | ||||||||||||
Chlorine Taste/Odor | 50% | reduction | 2.0 | mg/L | 2.0 mg/L | _+10% | 0.08 | mg/L ** | 2.0 | mg/L | 95.93 |
| 97.36 |
| ||||||||
Particulate | Class I* | 85% | reduction | 3533333#/mL | At east 10,000 part c es/mL | 22000 | #/mL | 11567 | #/mL | 99.38 |
| 99.67 |
| |||||||||
Contaminant |
| NSF Reduction | Average | Influent | Challenge | Maximum | Average | Minimum | % | Average | % | |||||||||||
Reduction |
| Requirements | Influent |
| Concentration | Effluent | Effluent | Reduction |
| Reduction | ||||||||||||
Lead: @ pH 6.5 | 0.010 | mg/L | 150 ug/L | 0.15 | mg/L | _+10% | 1.0 | ug/L | 1 ug/L |
| 99.33 |
| 99.33 |
| ||||||||
Lead: @ pH | 8.5 | 0.010 | mg/L | 157 ug/L | 0.15 | mg/L | _+10% | 2.0 | ug/L | 1.08 | ugiL | 98.72 |
| 99.31 |
| |||||||
Mercury: | @ pH 6.5 | 0.002 | mg/L | 0.0058 | mg/L | 0.006 | mg/L | _+10% | 0.0002 | mg/L | 0.0002 | mg/L | 96.53 |
| 96.53 |
| ||||||
Mercury: | @ pH 8.5 | 0.002 | mg/L | 0.0057 | mg/L | 0.006 | mg/L | _+10% | 0.0002 | mg/L | 0.0002 | mg/L | 96.5 |
| 96.5 |
| ||||||
Benzene |
|
| 0.005 | mg/L | 15 ug/L |
| 0.015 | mg/L | _+10% | 0.5 | ug/L | 0.5 | ug/L | 96.67 |
| 96.67 |
| |||||
0.6 mg/L | 1750 ug/L | 1.8 _+10% |
| 1.0 | ug/L | 1.0 | ug/L | 99.94 |
| 99.94 |
| |||||||||||
Toxaphene |
| 0.003 | mg/L | 15 ug/L |
| 0.015 | _+10% | 1.0 | ug/L | 1.0 ug/L | 93.33 |
| 93.33 |
| ||||||||
Atrazine |
|
| 0.003 | mg/L | 10 ug/L |
| 0.009 | mg/L | _+10% | 2 ug/L |
| 2 ug/L |
| 80.8 |
| 80.8 |
| |||||
Asbestos |
|
| 99% |
| 101 MFL | 107to | 108fibers/L tt | 0.17 | MFL | 0.17 | MFL | 99.83 |
| 99.83 |
| |||||||
Live Cysts _ |
| >99.95% | 120,000/L | 50,000/L | min. | 8/12 |
|
| 1/L _ |
| 99.99 |
| >99.99 |
| ||||||||
Turbidity |
|
| 0.5 NTU | 11.4 NTU | 11 _+1 NTU | 0.41 | NTU | 0.24 | NTU | 96.4 |
| 97.89 |
| |||||||||
Alachlor |
|
| 0.002 | mg/L | 41.3 | ug/L | 0.04 | _+10% | 0.2 | ug/L | 0.2 ug/L | 99.52 |
| 99.52 |
| |||||||
Endrin |
|
| 0.002 | mg/L | 5.9 | ug/L | 0.006 | _+10% | 0.5 | ug/L | 0.3 | ug/L | 91.5 |
| 95.47 |
| ||||||
Ethylbenzene |
| 0.7 mg/L | 1867 ug/L | 2.1 _+10% |
| 0.70 | ug/L | 0.0588 | ug/L | 99.96 |
| 100 |
| |||||||||
Lindane |
|
| 0.002 | mg/L | 1.9 | ug/L | 0.002 | _+10% | 0.02 | ug/L | 0.02 | ug/L | 98.93 |
| 98.93 |
| ||||||
Chlorobenzene | 0.6 mg/L | 2.0 | ug/L | 2.0 _+10% |
| 0.0005 | ug/L | 0.0005 | ug/L | 99.98 |
| 99.98 |
| |||||||||
Tetrachloroethylene | 0.005 | mg/L | 14.2 ug/L | 0.015 | _+10% | 0.5 | ug/L | 0.5 | ug/L | 96.47 |
| 96.47 |
| |||||||||
TTHM |
|
| 0.080 | mg/L | 465 | ug/L | 0.45 | _+20% | 1.0 | ug/L | 0.5 | ug/L | 99.78 |
| 99.88 |
| ||||||
MTBE |
|
| 0.005 | mg/L | 14 ug/L |
| 0.015 | _+20% | 0.70 | ug/L | 0.52 | ug/L | 94.94 |
| 96.27 |
| ||||||
VOC |
|
| 0.015 | mgiL | 0.3520 | mg/L | 0.300 | _+10% | 0.0060 | mg/L | 0.0008 | mg/L | 98.4 |
| 99.78 |
|
Test Parameters: pH = 7.5 + 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to 22°C).
•It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised.
•Model T1KBI: The filter monitor system measures the amount of
water that passes through the filter and alerts you to replace the filter.
Style 1 - When the filter indicator reads 10%, order a new filter. When the filter indicator reads 0%, it is recommended that you replace the filter.
•Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
•Refer to the front cover or "Accessories" section for the Manufacturer's name, address and telephone number.
•Refer to the "Warranty" section for the Manufacturer's limited warranty.
Style 2 - When the filter indicator light changes from green to yellow, order a new filter. When the filter indicator light changes from yellow to red, it is recommended that you replace the filter. Use replacement cartridge T1RFKB1, part #9030. In Canada, use replacement cartridge T1RFKB1, part #9030B. 2007 suggested retail price of $41.99 U.S.A./S51.99 Canada. Prices are subject to change without notice.
•These contaminants are not necessarily in your water supply. While testing was performed under standard laboratory conditions, actual performance may vary.
| Application | Guidelines/Water | Supply | Parameters | |
Water | Supply | City | or Well |
|
|
Water | Pressure | 30 - 120 psi (207 - | 827 kPa) | ||
Water | Temperature | 33 ° - 100°F | (0.6 ° - | 37.8°C) | |
Service | Flow Rate | 0.5 | gpm (1.9 | L!rain) | @ 60 psi |
•The product is for cold water use only.
*Class I particle size: >0.5 to <1 um
**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust. ttFibers greater than 10 um in length
_Based on the use of Cryptosporidium parvum oocysts
® NSF is a registered trademark of NSF International.
24