PERFORMANCE DATA SHEET

PERFORMANCE DATA SHEET

Base Grille Water Filtration System

Model TIKB1/TIRFKB1 Capacity 100 Gallons (379 Liters)

@System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of Chlorine Taste and Odor, Particulate Class I*; and against NSF/ANSl Standard 53 for the reduction of

Lead, Mercury, Atrazine, Benzene, Toxaphene, O-Dichlorobenzene, Cysts, Turbidity, Asbestos, Lindane,

Tetrachloroethylene, Endrin, Alachlor, Chlorobenzene, Ethylbenzene, TI-HM, MTBE and VOC.

 

This

system

has

been tested

according

to

NSF/ANSl

Standards

42 and

53 for the reduction of the substances listed below. The

 

 

concentration

of the

indicated

 

substances

in water entering

the

system

was

reduced

to

a concentration

less than or equal to the

 

 

permissible

limit

for

water

leaving

the

system,

as specified

in NSF/ANSl

 

Standards 42 and 53.

 

 

 

 

 

 

 

 

 

 

 

Substance

Reduction

NSF Reduction

 

Average

 

Influent

Challenge

 

 

Maximum

 

Average

Minimum

%

 

Average

%

 

Aesthetic

Effects

 

 

Requirements

 

Influent

 

 

Concentration

 

 

 

Effluent

 

Effluent

 

Reduction

 

Reduction

 

Chlorine

Taste/Odor

 

 

50%

 

reduction

 

2.0

mg/L

 

2.0 mg/L

_+10%

 

 

 

0.08

mg/L

 

2.0

mg/L

95.93

 

 

 

97.36

 

 

Particulate

Class

I*

 

 

85%

 

reduction

 

3533333#/mL

At

east 10,000 part

c es/mL

22000

#/mL**

11567 #/mL

99.38

 

 

 

99.67

 

 

Contaminant

 

 

 

 

NSF Reduction

 

Average

 

Influent

Challenge

 

 

Maximum

 

Average

Minimum

%

 

Average

%

 

Reduction

 

 

 

 

 

Requirements

 

Influent

 

 

Concentration

 

 

 

Effluent

 

Effluent

 

Reduction

 

Reduction

 

Lead: @ pH

6.5

 

 

 

0.010

rng/L

 

 

150 ug/L

 

0.15

mg/L

_+10%

 

 

 

1.0 ug/L

 

1 ug/L

 

99.33

 

 

 

99.33

 

 

Lead: @ pH

8.5

 

 

 

0.010

mg/L

 

 

157 ug/L

 

0.15

mg/L

_+10%

 

 

 

2.0 ug/L

 

1.08

ug/L

98.72

 

 

 

99.31

 

 

Mercury:

@ pH 6.5

 

 

0.002

mg/L

 

 

0.0058

mg/L

 

0.006

mg/L

_+10%

 

 

0.0002

mg/L

0.0002

mg/L

96.53

 

 

 

96.53

 

 

Mercury:

@ pH 8.5

 

 

0.002

mg/L

 

 

0.0057

mg/L

 

0.006

mg/L

_+10%

 

 

0.0002

mg/L

0.0002

mg/L

96.5

 

 

 

96.5

 

 

Benzene

 

 

 

 

 

 

0.005

mg/L

 

 

15 ug/L

 

 

0.015

mg/L

_+10%

 

 

0.5 ug/L

 

0.5

ug/L

96.67

 

 

 

96.67

 

 

O-Dichlorobenzene

 

 

0.6 mg/L

 

 

 

 

1750 ug/L

 

1.8 _+10%

 

 

 

 

1.0 ug/L

 

1.0

ug/L

99.94

 

 

 

99.94

 

 

Toxaphene

 

 

 

 

 

0.003

mg/L

 

 

15 ug/L

 

 

0.015

_+10%

 

 

 

1.0 ug/L

 

1.0 ug/L

 

93.33

 

 

 

93.33

 

 

Atrazine

 

 

 

 

 

 

0.003

mg/L

 

 

10 ug/L

 

 

0.009

mg/L

_+10%

 

 

2 ug/L

 

 

2 ug/L

 

80.8

 

 

 

80.8

 

 

Asbestos

 

 

 

 

 

99%

 

 

 

 

 

 

101 MFL

 

107to

108fibers/L _t

 

 

0.17

MFL

 

0.17

MFL

99.83

 

 

 

99.83

 

 

Live

Cysts _

 

 

 

 

>99.95%

 

 

 

 

120,000/L

 

50,000/L

min.

 

 

 

8/12

 

 

 

1/L _

 

99.99

 

 

 

>99.99

 

 

Turbidity

 

 

 

 

 

 

0.5 NTU

 

 

 

 

11.4 NTU

 

11 _+1 NTU

 

 

 

0.41

NTU

 

0.24

NTU

96.4

 

 

 

97.89

 

 

Alachlor

 

 

 

 

 

 

0.002

mg/L

 

 

41.3

ug/L

 

0.04

_+10%

 

 

 

0.2 ug/L

 

0.2 ug/L

 

99.52

 

 

 

99.52

 

 

Endrin

 

 

 

 

 

 

0.002

mg/L

 

 

5.9

ug/L

 

0.006

_+10%

 

 

 

0.5 ug/L

 

0.3

ug/L

91.5

 

 

 

95.47

 

 

Ethylbenzene

 

 

 

 

0.7 mg/L

 

 

 

 

1867 ug/L

 

2.1 _+10%

 

 

 

 

0.70

ug/L

 

0.0588

ug/L

99.96

 

 

 

100

 

 

Lindane

 

 

 

 

 

 

0.002

mg/L

 

 

1.9

ug/L

 

0.002

_+10%

 

 

 

0.02

ug/L

 

0.02

ug/L

98.93

 

 

 

98.93

 

 

Chlorobenzene

 

 

 

0.6 mg/L

 

 

 

 

2.0

ug/L

 

2.0 _+10%

 

 

 

 

0.0005

ug/L

0.0005

ug/L

99.98

 

 

 

99.98

 

 

Tetrachloroethylene

 

 

0.005

mg/L

 

 

14.2 ug/L

 

0.015

_+10%

 

 

 

0.5 ug/L

 

0.5

ug/L

96.47

 

 

 

96.47

 

 

TTHM

 

 

 

 

 

 

0.080

mg/L

 

 

465

ug/L

 

0.45

_+20%

 

 

 

1.0 ug/L

 

0.5

ug/L

99.78

 

 

 

99.88

 

 

MTBE

 

 

 

 

 

 

0.005

mg/L

 

 

14 ug/L

 

 

0.015

_+20%

 

 

 

0.70

ug/L

 

0.52

ug/L

94.94

 

 

 

96.27

 

 

VOC

 

 

 

 

 

 

 

0.015

mg/L

 

 

0.3520

mg/L

 

0.300

_+10%

 

 

 

0.0060

mg/L

0.0008

mg/L

98.4

 

 

 

99.78

 

Test Parameters: pH = 7.5 + 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).

 

 

 

 

 

 

Temp.

= 68°F to

71.6°F

(20°C

to

22°C).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

It is

essential

that

operational,

 

maintenance,

and

filter

 

 

 

 

 

 

system.

Systems

certified

for

cyst

reduction

may

be

used on

 

 

replacement

requirements

 

be carried

out for

the product

to

 

 

 

disinfected

waters

that

may contain

filterable

 

cysts.

 

 

 

perform

 

as advertised.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refer to the front cover or

"Accessories"

section

for

the

 

Model

T1KB1 : The

filter

monitor

system

measures

the

amount

of

 

Manufacturer's

name,

address

and

telephone

 

number.

 

 

water that passes through the filter and alerts you to replace the

 

Refer to the

"Warranty"

section for

the

Manufacturer's limited

 

 

filter.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

warranty.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Style

1 -

When

the filter

indicator reads 10%, order a new filter.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When the filter

indicator

reads

0%,

it is

recommended

that

you

 

 

 

Application

Guidelines/Water

Supply

 

Parameters

 

 

replace

the filter.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Style 2 - When the filter indicator light changes from green to

 

 

Water

Supply

 

 

 

 

 

City

or Well

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

yellow,

order

a

new

filter. When

the

filter

indicator

light

changes

 

Water

Pressure

 

 

 

 

 

30 -

120 psi (207 - 827 kPa)

 

 

from

yellow

to

red, it is recommended

 

that you replace

 

the

filter.

 

Water

Temperature

 

 

 

 

33 ° - 100°F (0.6 ° - 37.8°C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Use

replacement

 

cartridge

T1RFKB1,

 

part

#9030.

In Canada, use

Service

Flow Rate

 

 

 

0.5

gpm

(1.9

L/min) @ 60 psi

 

 

replacement cartridge T1 RFKB1, part #9030B. 2008 suggested

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

retail

price of $41.99

U.S.A./S51.99

 

Canada. Prices are subject to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

change

without

notice.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

These contaminants are not necessarily in your water supply. While testing was performed under standard laboratory conditions, actual performance may vary.

The product is for cold water use only.

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the

*Class I particle size: >0.5 to <1 um

**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust. t+Fibers greater than 10 um in length

_Based on the use of Cryptosporidium parvum oocysts ® NSF is a registered trademark of NSF International.

22

Page 22
Image 22
Kenmore WIOI67097A manual Performance Data Sheet, Base Grille Water Filtration System