Operation to reset

The microprocessor may fall into malfunction (impossibility to operate erroneous display, etc.) when the power cord is unplugged while power is ON or due to an external factor. In this case, execute the following procedure to reset the microprocessor and return it to normal condition.

With the POWER key left to ON, unplug the power cord from the power outlet then, while holding the eject (0) key depressed, plug the power cord again.

ÖPlease note that resetting the microprocessor clears the contents stored in, it returns the microprocessor to the condition when it left the factory.

Symptoms related to MD standard

Symptom

Cause

“DISC FULL” is displayed while the disc still has a remaining record-

ÖMore than 255 tracks (track No. 256 or more) cannot be recorded. (There

able time.

may be also cases in which recording is impossible while the track

 

number is less than 256.)

 

In such a case, the REMAIN time display shows “0:00”.

 

 

The recordable time does not increase after a short track has been

ÖThe remaining time display becomes “0:00” when the actual total

erased.

remaining time of the Mini Disc is less than 12 seconds. The recordable

 

time display changes when the total time of the erased track exceeds

 

12 seconds.

 

ÖWhen a Mini Disc has been subjected to repeated editing, the remaining

 

time may not increase even after a short track has been erased.

 

 

Tracks cannot be combined.

ÖA track created as a result of an editing operation may sometimes be

 

impossible to be combined with another track.

 

 

The total of the recorded time and recordable time does not coincide

ÖAs recording is performed on a minimum recording basis of 2 seconds,

with the total recording time of the MD (60 or 74 min.).

the displayed time may not coincide with the consumed disc capacity.

 

 

Sound is interrupted when a track created by editing is subjected to

ÖSound interruption may occur due to a combination of various factors,

fast forward or fast backward operation.

and it is not a malfunction.

 

 

 

ÖA short track may be created depending on the contents of the recorded

Tracks are not numbered correctly.

source (CD, for example).

 

 

The period in which “READING” is displayed is abnormally long.

Ö“READING” is displayed for a longer period than usual when a brand-

 

new recordable Mini Disc (a virgin disc) is loaded.

 

ÖThe Mini Disc in use has been processed with repeated editing or

 

contains a large number of tracks.

 

 

The total number of characters used in the titles is less than 1792

ÖAs the title recording areas are used on a per-7-character basis, the total

characters.

number of input characters may be less than 1792.

 

 