Status Information Display and Settings

Displays the operating voltage, current consumption and internal temperature.

Additionally, changes the units for temperature or turns ON/OFF the demonstration.

Display type

Control knob

DISP switch

1Slide the DISP switch towards INFO. “INFO” appears on the display for 1 second.

2Turn the control knob to change the display type in the following order.

Display

Information / Function

“VOLT”

Displays the operating voltage (V).

“CURRT”

Displays the current consumption (A).

“TEMP”

Displays the internal temperature (°C / °F).

“DEMO”

Sets demonstration display ON / OFF.

NOTE

Temperatures lower than -22°F or -30°C are displayed as “-22F” or “-30C” respectively.

Displayed information may differ from actual conditions.

Changing the units for temperature

Select °F (Fahrenheit) or °C (Celsius).

1Turn the control knob, display “TEMP” and push the control knob.

2Turn the control knob, display “---F” (Fahrenheit) or “---C” (Celsius) and push the control knob.

NOTE

The default setting is “---F” (Fahrenheit).

Turning DEMO ON/OFF

Turn the demonstration function ON to display “VOLT”, “CURRT” and “TEMP” information. The demonstration display changes every five seconds.

1Turn the control knob, display “DEMO” and push the control knob.

2Turn the control knob, display “ON” or “OFF” and push the control knob.

NOTE

The default setting is “OFF”.

English 7