TK-7150
41
Item Condition
Measurement Adjustment
Specifications/Remarks
Test-
equipment Unit Terminal PartsUnit Method
ADJUSTMENT
• Narrow 4)CH-SIG : 2-1
Power meter
Rear ANT Front
Selector
±1.75kHz ±0.05kHz
[PF5] key : Set the narrow Deviation panel panel knob
n_L meter
Max_Dev_ _✽✽✽
in tuning mode AF VTVM Front MIC
PTT : ON AG panel
Oscilloscope
5)CH-SIG : 1-1
Select n_C
Max_Dev_ _✽✽✽
in tuning mode
PTT : ON
6)CH-SIG : 3-1
Select n_H
Max_Dev_ _✽✽✽
in tuning mode
PTT : ON
11. MIC 1) CH-SIG : 1-1 TX-RX VR700 Check 2.2~3.7kHz
seisitivity PTT : ON
(Wide only) Deviation meter filter
HPF : OFF
LPF : 15kHz
De-emphasis : OFF
AG : 1kHz/5mV
12. DQT 1)CH-SIG : 1-1 Front
Selector
Wide/Narrow Flat the A parts.
balance Select DQT_Bal_ _✽✽✽ panel knob Make the
• Wide in tuning mode demodulation wave-
PTT : ON form neat.
Deviation meter filter
HPF : OFF
LPF : 3kHz
De-emphasis : OFF
• Narrow 2)[PF5] key : Set the narrow
n_ _
DQT_Bal_ _✽✽✽
in tuning mode
PTT : ON
13. QT 1)CH-SIG : 1-3 ±0.75kHz ±0.05kHz
deviation Select QT_Dev_ _ _✽✽✽
• Wide in tuning mode
PTT : ON
Deviation meter filter
HPF : OFF
LPF : 3kHz
De-emphasis : OFF
• Narrow 2)[PF5] key : Set the narrow ±0.35kHz ±0.05kHz
n_ _
QT_Dev_ _ _✽✽✽
in tuning mode
PTT : ON
A
A