TK-7150
44
CN201
CN202
VR700
VR1
L201
1
2
L205
L206
CV
L207
L208
L209
L210
1
2
TC501
TX
TC502
RX
CV
7. Adjustment Points

7-1. Component Side View 7-2. Foil Side View

VR1 : TX high power (High)
VR700 : MIC seisitivity
TC501 : PLL lock voltage (TX)
TC502 : PLL lock voltage (RX)
L201 : AF coil adjustment
L205,207,209 : MCF (Wide)
L206,208,210 : MCF (Narrow)
Item Condition
Measurement Adjustment Specifications/
Remarks
Test-
equipment Unit Terminal PartsUnit Method
ADJUSTMENT
21. Squelch 1)CH-SIG : 1-1 SSG Rear ANT Front
Selector
Adjust to point of Set the value to 255.
open Select Sql_O_ _ _ _✽✽✽ panel panel knob opening squelch Adjust the SSG out-
• Wide in tuning mode put to “Condition”.
SSG output : Value when 3dB AF VTVM EXT.SP Then, decrease the
is subtracted from the Distortion value to the point of
sensitivity value of 12dB meter opening the squelch.
SINAD.
Oscilloscope
4 dummy
• Narrow 2) [PF5] key : Set the narrow load
n_ _
Sql_O_ _ _ _✽✽✽
in tuning mode
SSG output : Value when 4dB
is subtracted from the
sensitivity value of 12dB
SINAD.
Wide/Narrow
3)SSG output : OFF Check Squelch must be
closed.
Note : When you change the Squelch adjustment value, connect all necessary measuring equipment (as stated in the adjustment procedure), then
adjust it to the SSG output value.