Function

Operation

Function

LED Display

Alarm Sound

Unit Status

Recommendation

 

 

 

 

 

Normal

Green LED constantly on

None

Normal AC operation

None

operation

 

 

(sensing no CO) and

 

 

 

 

with a good battery

 

 

 

 

 

 

Normal

Green LED flashes every

None

Normal DC operation

Verify AC power is

operation

7 seconds

 

on 9V battery backup

restored as soon as

 

 

 

 

possible to conserve

 

 

 

 

battery. Replace battery

 

 

 

 

 

Carbon

Red LED flashes with

4 quick beeps,

Alarm condition.

Refer to alarm

monoxide

beeps. Amber LED shows

5 seconds silence,

Dangerous

procedure on

alarm

initiating alarm

repeating

concentrations of CO

Page 17

 

 

 

detected

 

 

 

 

 

 

Smoke / fire

Red LED flashes with

3 long beeps,

Receiving signal from

Evacuate by your

alarm

beeps.

1 second silence,

an interconnected

escape plan

 

 

repeating

smoke alarm detecting

 

 

 

 

smoke

 

 

 

 

 

 

Low battery

Red LED flashes every

One short “chirp”

AC powered and low or

 

15 seconds

every 15 seconds

missing battery

Install or replace 9V battery. Refer to Page 14

Error / service

Red LED flashes every

One short “chirp”

Unit malfunction

Call Kidde

alarm

30 seconds

every 30 seconds

 

Customer Service

 

 

 

 

 

Error

Red LED constantly on

Constant alarm

Very low battery or unit

Replace 9V battery. If

 

 

 

malfunction. Unit will

condition continues,

 

 

 

not respond to CO

call Kidde Customer

 

 

 

 

Service

 

 

 

 

 

Normal Test/Reset function

Red LED flashes with

4 quick beeps,

beeps. Green and amber

5 seconds silence,

LED’s on

repeated once

Normal operation

CO not detected.

when Test/Reset button

Alarm for test

is pressed

purposes only