Tamper Resist Feature

Installation

Turn on the A.C. power. The green A.C. Power On Indicator should be lit when the alarm is operating from A.C. power.

For alarms equipped with 9V battery backup: Pull the Battery Pull Tab (yellow tab protruding from unit) com- pletely out of unit. This will automatically connect the battery.

Tamper Resist Feature

To make this CO alarm somewhat tamper resistant, a tamper resist feature has been provided. Activate the feature by breaking off the four posts in the square holes in the mount- ing plate (see Figure 3A). When the posts are broken off, the tamper resist tab on the base is allowed to engage the mount- ing plate. Rotate the alarm onto the mounting plate until you hear the tamper resist tab snap into place, locking the alarm.

Using the tamper resist feature will deter children and others from removing the alarm. To remove the alarm, press on the tamper resist tab, and rotate the alarm off of the mounting plate (see Figure 3B).

TAMPER RESIST FEATURE

FIGURE 3A

 

FIGURE 3B

 

 

 

Location

of Posts

AA