Kirby manual Section, Trouble Shooting the KMACS 5 System, General, No Communications, Symptoms

Models: 5 Air Control System

1 31
Download 31 pages 58.17 Kb
Page 23
Image 23
Section 4.0

Section 4.0

KMACS 5 MANUAL

Trouble Shooting the KMACS 5 System

4.1 GENERAL

The KMACS 5 is an extremely simple system which should not malfunction if the instructions in this manual are followed. Most problems encountered in using the system can be easily remedied. The following informa- tion covers the common operating difficulties.

4.2 NO COMMUNICATIONS

Symptoms

Probable Cause(s)

Remedy

 

 

 

1) No sound at either KMACS 5 or

a)Communication power not on.

Activate switch and adjust volume.

 

diver’s mask.

 

 

 

 

b) Communications incorrectly

Switch terminal wires.

 

 

hooked up.

 

 

 

c) Communications not hooked up.

Plug into terminals.

 

 

 

 

 

2) Battery indicator does not re-

Battery low or dead.

Charge or replace battery, or

spond.

 

bypass battery with external power.

 

 

 

 

3) Communications weak or broken

Terminals covered with corro-

Clean Terminals with wire brush to

 

up.

sion.

bright shiny metal.

 

 

 

 

 

4) Communications will not work

Headset not working

Replace headset.

with headset but works otherwise.

Short in internal wiring.

Return to factory for repair

 

 

 

 

5) Communications interrupted

Break in diver’s communication

Splice wire if damage is minor. Re-

 

when umbilical is moved.

wire.

place wire if damage is major.

 

 

 

 

 

6)Communications interrupted when waterproof connector is moved.

Break in splice at waterproof

Replace splice or connector.

connector or failure of connector.

 

Test with VOM.

 

7) Satisfactory communications a) One wire in cable is broken through one earphone or micro-

phone only (4 wire mode).

b) Microphone/earphones dead.

Stack connectors in microphone terminals. Communications works in two wire mode.

Replace microphone/earphones.

8) No sound at either KMACS 5 Communicator not functional.

Return to

factory for repair after

or mask.

verifying

no cure by following

 

above procedures.

© 2003 KMDSI Document # 041112001