Kirby Air Control System, 5 No Pneumo Reading, Symptoms, Probable Cause, Remedy, No Air To Diver

Models: 5 Air Control System

1 31
Download 31 pages 58.17 Kb
Page 24
Image 24
4.3 NO PNEUMO READING

KMACS 5 MANUAL

 

4.3 NO PNEUMO READING

 

 

 

 

Symptoms

Probable Cause

Remedy

 

 

 

 

 

 

 

1) No air to diver’s end of pneumo

Pnuemo hose not connected

Attach fittings to KMACS 5

 

 

 

 

 

 

 

2) Gauge reads sustained pressure

Pneumo crimped or plugged.

Check entire length of hose.

 

 

at surface.

 

Relieve any restrictions.

 

 

 

 

 

 

 

3) Hose will not hold pressure and

Pneumo fitting cracked or loose.

Check fittings at console with

 

 

gauge needle will not rise.

 

soap and water solution. If fittings

 

 

 

 

bubble, either tighten or replace

 

 

 

 

as necessary.

 

 

 

 

 

 

 

4) Needle will not respond properly

a) Hole in pneumo hose.

Check hose; replace or splice as

 

 

to flow.

 

necessary.

 

 

 

b) Gauge mechanism damaged.

Replace or repair gauge. Return

 

 

 

 

to factory.

 

5)Air can be heard escaping into console interior.

KMACS 5 internal plumbing may Return to factory for service. be cracked or broken.

4.4 NO AIR TO DIVER

Symptoms

Probable Cause

Remedy

1)No hose pressure in diver’s umbilical

a)primary air source not con- nected.

b)Valve closed at low pressure source

Connect proper hose to console.

Open valve at low pressure com- pressor.

 

c) Selector valve in “H.P. OFF”

Move selector valve handle in

 

zone.

 

line with flow from either high

 

 

 

 

pressure source.

 

 

 

2) No gauge reading on high

Valve closed at high pressure

Open valve at high pressure

pressure gauge.

source

source.

 

 

 

3) Low hose pressure in diver’s

Regulator not properly loaded.

Rotate adjustment wheel in ap-

umbilical.

propriate direction.

4) Air can be heard escaping

Fitting loose on diver’s hose, or

Tighten fittings until snug. Do

from hose.

fittings damaged.

not over tighten. Replace fittings

 

 

 

if damaged.

 

 

 

5) Umbilical registers pressure

Mask improperly serviced.

Clean and adjust mask.

at console gauge, but no flow

 

 

at mask.

 

 

18

© 2003 KMDSI Document # 041112001

 

Page 24
Image 24